CAUTION: Make sure the unit is at a safe temperature and is
isolated from gas and electrical supplies before
beginning.
For your safety, exercise caution, and make sure you have
adequate hand protection, such as gloves, when handling metal
parts.
CONVERT LABEL
This unit comes from the factory confi gured for one type of gas
as marked on the label behind the control panel.
When the unit is converted, the label for the new gas
(included at original shipping) MUST be applied over the
old label mentioned above.
CONVERT REGULATOR
The gas regulator, located behind the control panel , must be set
for the type of gas used to fuel the unit. To check the regulator
setting, remove the cap in the center of the regulator (Fig. 23-1,
A). Holding the cap vertical (see Fig. 23-2, B), the letters at the
bottom of the plastic stalk indicate the gas type for which the
regulator is currently confi gured.
If the text on the bottom of the regulator stalk does not match
the gas type connected to the unit, remove the stalk from the
cap, invert, and replace into center of cap. Replace cap on the
regulator, screwing down until snug.
CONVERT GAS ORIFICES
When converting the unit to a different gas type, each burner’s
orifi ce must be replaced with the corresponding orifi ce for the
new gas.
See MODEL SPECIFICATIONS TABLE, Table 1 at the beginning
of this document to determine the proper orifi ce
sizes for each
burner.
Important: It is critical to the operation of each burner that
its orifi ce be fully inserted into the center of
its orifi ce opening.
WARNING
HAZARDOUS OVERHEATING WILL OCCUR IF A NATURAL-
GAS ORIFICE IS USED WITH PROPANE GAS.
CONNECT TO NEW GAS SUPPLY
Plumb the unit as appropriate for the new gas supply. (Additional
components may be needed for your specifi c setup.) Be sure
to leak test at all connections.
A
B
Invert if
needed
Gas regulator cap
Read gas
type here
(LP shown)
Fig. 23-1 Convert regulator
CONVERT GAS TYPE / CHECK BURNER ORIFICES