Owners Manual

17
PROBLEM POSSIBLE CAUSE CORRECTION
Ignition system
failure
1) Improper air shutter adjustment 1) Adjust air shutters.
2) Ignition wire disconnected 2) Replug wires into generator.
3) Low gas pressure 3) Adjust or replace battery.
4) Igniter switch malfunction 4) Contact dealer for replacement.
Insuffi cient heat
1) Improper air shutter adjustment 1) Adjust air shutters.
2) Using propane orifi ce for natural gas 2) Change orifi ces.
3) Low gas pressure/fl ame (natural) 3) Have gas company check the
operating pressure at the unit.
4) Low gas pressure/fl ame (propane) 4) Refill propane tank, or reset
propane tank safety*: Shut off all
valves (including propane tank) and
follow lighting instructions exactly.
Uneven heating
1) Burner ports partially blocked by debris 1) Remove burners and clean out ports.
2) Small spiders or insects in burner 2) Inspect burners for spider webs or
other debris that may block gas fl ow.
Burner goes out on
LOW
1) Valve “Low” setting needs
adjustment
1) Light burner on HIGH, immediately
turn to LOW setting. Remove
knob from valve and using a small
flat screwdriver, slowly turn the
adjustment screw in the stem,
a little at a time (30° to 45°), in
either direction, until the fl ame is
approximately
1
/
4
in height from
burner ports.
Knob light(s) not
operating
1) Light switch off
2) Knob light(s) burned out
1) Turn light switch on
2) Contact dealer for replacement.
Rotisserie noisy
1) Rotisserie out of balance 1) Adjust counterbalance.
If you have trouble with the unit, please use this list to identify the problem. By trying one or more of the
solutions to the possible cause, you should be able to solve the problem. If this list does not cover your
present problem, or if you have other technical diffi culties with the unit, please contact your local dealer.
TROUBLESHOOTING
Note: *Propane tanks are equipped with a safety shutdown device that may cause low or no gas/fl ame
at the burners if operating and lighting instructions are not followed exactly. If you suspect the
propane tank safety shutoff is in effect, shut off all burner control valves and the propane tank
valve. Then read and follow the LIGHTING INSTRUCTIONS exactly. Lighting instructions are
located in the owner’s manual. If the problem persists, continue troubleshooting, or contact your
local dealer or distributor for assistance.