ENCLOSURE REQUIREMENTS
VENTILATION (ALL ENCLOSURES)
For All Piping Systems and All Gas Types:
(Natural Gas, Household Propane, L.P. Cylinder)
FOR YOUR SAFETY, you must provide the openings listed
below for replacement air and cross-ventilation of the
unit enclosure.
One side of the enclosure shall be left completely open to
the outside; OR 4 (minimum) ventilation openings MUST
be created (reference Fig. 11-1):
Each opening must have a minimum of 10 sq. in. of
free area. The openings must be equally sized and
unobstructed.
Two openings must be in the side walls of the enclosure, at
the top level, and spaced at 180 degrees. The openings must
begin 1" or less below the countertop level and end no more
than 5" below the countertop level.
Two openings must be in the side walls of the enclosure, at
the fl oor level, and spaced at 180 degrees. The openings must
begin 1" or less above the fl oor level and end no more than
5" above the fl oor level.
To achieve the proper ventilation, you may use RHP venting
panels (PN 5510-01) as shown. Contact your dealer.
KEEP THE VENT OPENINGS AND SURROUNDING
AREA OF THE ENCLOSURE CLEAN AND FREE OF
OBSTRUCTIONS AT ALL TIMES.
WARNING: Ventilation openings in side walls shall not
communicate directly with other enclosures of
the outdoor cooking gas appliance.
WHEN A PROPANE (L.P.) CYLINDER IS USED IN
THE ENCLOSURE
When a propane (L.P.) cylinder is installed inside of the
enclosure, the guidelines below MUST be followed. FAILURE
TO DO SO MAY CAUSE DAMAGE TO YOUR UNIT AND/OR
PERSONAL INJURY. Reference Fig. 11-2 for an example.
Only a C.S.A. listed stainless steel connector can be
connected to the unit.
The regulator/hose assembly coming from the propane
cylinder can only be connected to the above mentioned
ex connector. DO NOT connect the regulator/hose
assembly directly to the unit. An adapter will be
required.
A heatshield must be installed to protect the regulator/
hose assembly and propane cylinder valve.
RHP offers propane tank door with tank tray models
(PN 23920-1T-S or 25914-S) to meet the cylinder
install requirements. See Fig. 11-3.
Fig. 11-1 Ventilation detail
Fig. 11-3 Optional RHP door w/ tank tray
Cylinder & regulator/hose assembly
protected by heatshield
Additional adapters may be required
for your setup (not included)
Equipped with adapter
for hose assembly and
ex connector
(not included)
Ventilation Requirements:
Minimum 4 openings
(2 per side wall - spaced at 180 degrees)
Top openings: within 5" of countertop (see below)
Bottom openings: within 5" of fl oor (see below)
1"
max.
Keep surrounding area
and vent openings clear
for proper venting
5"
max.
1"
max.
5"
max.
23920-1T-S
model shown
Vent openings (4)
10 sq. in. of free
area min. (ea.)