COUNTER PREPARATION
Consult Table 1 for non-combustible enclosure cut-out
dimensions. A RHP insulating liner must be used if any
supporting construction is combustible. Consult the instructions
that come with the liner for dimensions and additional
installation information before beginning the installation.
This power burner must be supported by the stainless-steel
hanger extending from the upper portion of the frame. The
hanger rests on the left, right, and back of the countertop.
The control panel is designed to sit fl ush against the enclosure
front wall (see Fig. 15-2). If the non-combustible enclosure
countertop extends beyond the front wall, creating a countertop
overhang (see Fig. 15-1), it must be cut fl ush with the front
wall for the width of the control panel or a gap will be created
exposing the forward portions of the left and right side fi re walls
of the unit. Reference the MODEL SPECIFICATIONS section.
Note: It is not necessary to remove the control panel or
knobs to install this unit.
CONNECT THE GAS SUPPLY
For propane cylinders:
For connecting a propane unit to a portable propane tank,
read the safety warnings and follow the instructions in the
section SAFE USE AND MAINTENANCE OF PROPANE GAS
CYLINDERS.
Note: When a propane cylinder is installed inside of the
enclosure, the guidelines found in the ENCLOSURE
REQUIREMENTS section MUST be followed.
For household propane or natural gas units:
CAUTION: Use only C.S.A. listed stainless-steel flex
connectors within the enclosure.
WARNING
A rubber or plastic connector will rupture or leak, resulting
in an explosion or serious injury if used inside the
appliance enclosure.
1. Locate the attached fl ex connector (found underneath the
unit) and route it to the gas-supply stub.
2. Turn OFF the gas supply at the source.
3. A shut-off valve is required within 6 feet of the unit.
If shut-off valve is connected to end of gas supply
stub:
Connect the fl ex connector to the shut-off valve (see
Fig. 15-3). Tighten securely.
If shut-off valve is installed in-line:
Install the supplied fl are adapter to the gas supply using
a pipe joint compound resistant to all gasses (see Fig.
15-3). Tighten securely.
Connect the fl ex connector to the fl are adapter (see
Fig. 15-3). Tighten securely.
OFF
To gas
system
Gas inlet pipe
Hanger
Countertop
Cut-out
Pipe adapter
Flex
connector
INSTALLATION
INSTALLATION
GAP CREATED
IDEAL
Flush-mounted
control panel
Proposed cut-
out in overhang
(Countertop)
(Countertop)
Overhang
Control panel
stops here
Fig. 15-1 Countertop overhang - incorrect cutout
Fig. 15-2 Countertop overhang - correct cutout
INCORRECT
CORRECT
Fig. 15-3 Connecting to a gas line
Gas supply
Flare adaptor
(use on gas
supply stub only
if shut-off
valve
installed in-line)
Flex connector
(coming from unit)
Shut-off valve
(required, not
included, must be
installed within 6 feet
of unit)
Fig. 15-4 Household propane & natural gas diagram
Shut-off valve
(shown in-line)
must be within 6