COUNTERTOP OVERHANG
The control panel is designed to sit fl ush against the enclosure front wall. If the non-combustible enclosure countertop extends beyond
the front wall, creating a countertop overhang, it must be cut fl ush with the front wall for the width of the control panel or a gap will be
created exposing the forward portions of the left and right side grill fi re walls. See illustrations above.
Important: FOR YOUR SAFETY, you must provide openings in the island enclosure for drainage, replacement air, and
cross-ventilation of any storage area exposed to possible leakage from gas connections, the unit, or propane
bottles. See the ENCLOSURE REQUIREMENTS section for details.
TOP VIEW
Countertop
Lower support
Countertop
overhang
Control panel
NON-COMBUSTIBLE
ENCLOSURE CUT-OUT
DIMENSIONS
Fig. 5-1
FRONT VIEW
B
C
D
See next page
for substrate
considerations
Countertop
overhang
X
TOP VIEW
SIDE VIEW
Countertop
overhang
(Control
panel)
(Countertop)
Y
1
/
4
"
Clearance
(Overhang)
X=
5
/8"
Y= Total
Countertop
Overhang
A
Control
panel
Check clearance for
control panel removal
MODEL SPECIFICATIONS TABLE
Table 1
Inner burner
N/P (right) orifi ce drill size
#46 / #1.25
Outer burner
N/P (left) orifi ce drill size
#30 / #50
Fire Magic insulating liner model # (not included)* 24182-51
Input electrical requirements
120VAC / 15 AMP minimum / 60 Hz / GFCI outlet
A Countertop to unit bottom cut-out* 12"
B Side to side non-combustible cut-out* 19"
C Front to back non-combustible cut-out*† 18
3
/
4
"
D Control panel width non-combustible cut-out 20
1
/
4
"
*Note: If installing this unit in a combustible enclosure, the correct insulating liner must be used. Consult liner
instructions for counter cut-out dimensions and installation.
Includes any substrate at front wall of enclosure (in the area the rear of the control panel is to sit fl ush against).
See SUBSTRATE section on next page.
Only applicable for non-combustible enclosures that have countertops with an overhang (see illustration and
section below).
Note: It is highly recommended to build the enclosure with an offset counter height for
the power burner installation. See the RECOMMENDED OFFSET INSTALL section
on the following page for details.
MODEL SPECIFICATIONS