Replacement Part List

Page 11
NOTE:
Total power drawn from all receptacles must not exceed the name plate rating.
Control Panel
English Customer Service: 1-844-FIRMAN1
3
4
2
1
5
6
7
8
9
10
2
3
4
1
3-1 Data-Minder(Multi-Meter) – Push the
SELECT button to show the Voltage, Hertz
and running hours.
5
6
120V, 30A Twist-Lock (NEMA L5-30R)
Maximum full load 30 Amp current may be
drawn from this 120 Volt receptacle.
7
Indicator Light
When the fuel selector switch is turned to the
GAS” or “LPG position, the indicator light will
become RED up to 4 minutes(before goes off).
Starting the engine successfully during these
4 minutes will turn the indicator light GREEN.
MUST HAVE SOLID RED INDICATOR LIGHT
TO BE ABLE TO START THE GENERATOR. THE
GENERATOR CANNOT BE STARTED DURING
BATTERY POWER SAVING MODE UNLESS
THE FUEL SELECTOR SWITCH IS TURNED TO
THE “OFF” POSITION AND THEN TURNED
BACK TO THE “GAS” OR “LPG” POSITION.
See Indicator light-Battery power Saving
Mode section for more information.
120V, 20A Duplex – (NEMA 5-20R)
Ground Terminal – Consult an electrician
for local grounding regulations.
Fuel Selector Switch – Use to select and turn
on gasoline or LPG fuel source. Fuel (gasoline)
valve is closed when the switch is on OFF” or
LPG” positions. Engine switch is on when the
switch is on “GASor “LPGpositions.
4
Maximum full load 20 Amp current may be
drawn from this 120 Volt receptacle.