9. TROUBLE SHOOTING
Page 21
Problem
Cause
Correction
Engine is running, but no
AC output is available.
Generator will not start
Engine will not start; starts
and runs rough or shuts
down when running.
Generator shuts down
during operation
Repeated circuit breaker
tripping
No fuel
Faulty spark plug
Unit loaded during start up
Low oil level
Choke in the wrong position
Spark plug wire loose
Out of fuel
Low oil level
Generator cannot supply
enough power or
overheating
Generator is overloaded
Insufficient ventilation
Overload
Faulty cords or device
Cable not properly connected
Connected device is defective
Loose wiring
Other
Check all connections
Replace defective device
Inspect and tighten wiring connections
Contact the help line
Add fuel
Replace spark plug
Remove load from unit
Fill crankcase to the proper level
Place generator on a flat, level surface
Adjust choke
Attach wire to spark plug
Fill fuel tank
Fill crankcase to the proper level.
Place generator on a flat, level surface
Review load and adjust. See “Power
Management
Check for air restriction. Move to a well
ventilated area
Review load and adjust. See “Power
Management
Check for damaged, bare or frayed wires.
Replace defective device