User Manual

Page 18
English Customer Service: 1-844-FIRMAN1
Low Oil Shutdown
If the engine oil drops below a preset level, an
oil switch will stop the engine. Check oil level
with dipstick.
If oil level is between the LOW and HIGH mark on
dipstick:
1.Add oil to bring level to HIGH mark.
2.Restart engine and if the engine stops again
a low oil condition may still exist. DO NOT try
to restart the engine.
3.Contact an Authorized FIRMAN Service Dealer.
4.DO NOT operate engine until oil level is
corrected.
Do Not Overload Generator
Overloading a generator in excess of its rated
wattage capacity can result in damage to the
generator and to connected electrical devices.
To prolong the life of your generator and
attached devices, follow these steps to add
electrical load:
1. Start the generator with no electrical load
attached.
2. Allow the engine to run for several minutes
to stabilize.
3. Plug in and turn on the first item. It is best to
attach the item with the largest load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.
Overload Operation
The overload indicator light will turn on when
the load exceeds 3000W(approximately). If the
load exceeds 3200W(approximately), the light
will blink and cut power to the receptacles in 30
seconds.
Parallel Operation
Two FIRMAN model W03081 generators can be
operated in parallel to increase the total available
electrical power to 5500 watts. A FIRMAN parallel
kit (optional equipment) is required for parallel
operation. For kit availability, call Customer Service
at 1-844-347-6261 or visit:www.firmangenerators.com.
1.DO NOT try to restart the engine.
2.Contact an Authorized FIRMAN Service Dealer.
3.DO NOT operate engine until oil level is corrected.
If oil level is below the LOW mark on dipstick:
1. Disconnect any electronic devices, and then
stop the engine.
2. Reduce the total wattage of connected
electronic devices until it is within the generator’s
rated output.
3. Inspect the Air Inlet and Control Panel for any
blockage. Remove blockage if found.
4. Restart Engine.
How to Correct
If a cover is used, do not install until unit has cooled.
3. Turn the fuel valve to the “OFF(O) position.
If the engine will not be used for a period of two
weeks or longer, please see the Storage section
for proper engine and fuel storage.
CAUTION
DO NOT disconnect parallel cable while
generator is running.