User Manual

Page 10
SPECIFICATIONS
AN IMPORTANT MESSAGE ABOUT TEMPERATURE:
Your Firman Power Equipment product is designed and rated for continuous operation at
ambient temperatures up to 40°C (104°F). When your product is needed, your product may be
operated at temperatures ranging from -15°C (5°F) to 50°C (122°F) for short periods. If the
product is exposed to temperatures outside this range during storage, it should be brought back
within this range before operation. In any event, the product must always be operated outdoors,
in a well-ventilated area and away from doors, windows and other vents.
When operated above 7F(2C) there may be a decrease in power.
Maximum wattage and current are subject to and limited by such factors as fuel BTU content
ambient temperature, altitude, engine condition and etc. Maximum power decreases about
3.5% for each 1,000 feet above sea level; and will also decrease about 1% for each 1F(6°C)
above 6F(16°C) ambient temperature.
Model
Rated AC Voltage
Phase
Power Factor
Voltage regulator
Alternator Type
Running Watts
Starting Watts
Engine
Engine Type
Displacement
Low Oil Shutdown
Ignition System
Starting System
Fuel
Capacity Fuel Tank
Lubricating Oil Capacity
Carburetor Type
Air Cleaner
P.T.O. shaft rotation
120V
W03082
3300
Digital
Single Phase
1
Single Cylinder, 4-Stroke OHV Air Cooled
171 cc
Breakless Ignition Type, Flywheel Magneto
Unleaded Automotive Gasoline
1.8 Gallon
20.3 oz(0.6L)
Counter Clockwise (Facing P.T.O.)
Float
Polyurethane Type
YES
3000
FIRMAN
Rated Fequency
60Hz
Oil Type
See “Add Engine Oil” Section
Spark Plug
TORCH F6RTC/NGK BPR6ES/CHAMPION RN9YC
English Customer Service: 1-844-FIRMAN1
Magneto Inductor
Recoil/Electric Start