User Manual

Page 13
Use approved transfer equipment to prevent
backfeed by isolating generator from electric
utility workers.
When using generator for backup power, notify
utility company.
Use a ground fault circuit interrupter (GFCI) in
any damp or highly conductive area, such as
metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords
which are worn,frayed, bare or otherwise
damaged.
DO NOT operate generator in the rain or wet
weather.
DO NOT handle generator or electrical cords
while standing in water, while barefoot, or
while hands or feet are wet.
DO NOT allow unqualified persons or children
to operate or service generator.
Connecting to a Building's Electrical System
Connections for standby power to a building's
electrical system must be made by a qualified
electrician. The connection must isolate the
generator power from utility power or other
alternative power sources and must comply
with all applicable laws and electrical codes.
WARNING
Generator voltage could cause
electrical shock or burn resulting
in death or serious injury.
English Customer Service: 1-844-FIRMAN1
Altitude main jet 1
Altitude main jet 2
171cc
330717002
330717003
Altitude
3000-6000Feet
6000-8000Feet
OPEN
WARNING
The part number and recommended minimum
altitude for the application of the high altitude
carburetor main jet is listed in the table below.
Grounding
The National Electric Code requires your generator
must be properly connected to an appropriate
ground to help prevent electric shock.
Failure to properly ground the
generator can result in electric
shock.
WARNING
A ground terminal connected to the frame of
the generator has been provided on the control
panel. For remote grounding, connect of a
length of heavy gauge (12 AWG minimum)
copper wire between the generator ground
terminal and a copper rod driven into the
THERE IS A PERMANENT CONDUCTOR BETWEEN
THE GENERATOR (STATOR WINDING) AND THE
FRAME.
adjusting the engine. At high altitudes increased
exhaust emissions can also result due to the increased
enrichment of the air fuel ratio. Other high altitude
issues can include hard starting, increased fuel
consumption and spark plug fouling. To alleviate
high altitude issues other than the natural power
loss, FIRMAN can provide a high altitude carburetor
main jet. The alternative main jet and installation
instructions can be obtained by contacting Customer
Support. Installation instructions are also available
in the Technical Bulletin area of the FIRMAN internet
site.
ground. We strongly recommend that you
consult with a qualified electrician to ensure
compliance with local electrical codes.