If engine starts after 3 pulls but fails to run, or if
unit shuts down during operation, make sure
unit is on a level surface and check for proper
oil level in crankcase. This unit may be equipped
with a low oil protection device. If so, oil must
be at proper level for engine to start.
Keep choke lever in “CHOKE” position for only 1
pull of the recoil starter. After first pull, move
choke lever to the RUNposition for up to the
next 3 pulls of the recoil starter. Too much
choke leads to sparkplug fouling/engine
flooding due to the lack of incoming air. This
will cause the engine not to start.
Starting the Generator (Electric Start)
2. Check oil level and fuel.
WARNING
WARNING
1. Before starting the generator, check for loose
or missing parts and for any damage which
may have occurred during shipment.
Electric Start Operations
This model is provided with recoil start and
electric start capabilities. The charger is a low
amperage maintenance type charger. It will
charge your battery as your generator runs.
Avoid prolonged cranking, as it can damage
the engine.
4. Turn the fuel valve to the “ON(l) position.
3. Disconnect all electrical loads from the
generator. Never start or stop the generator
with electrical devices plugged in or turned on.
5. Pull the choke lever out to the "CHOKE" position.
6. Press and hold the engine switch in the "START"(ll)
position for few seconds and release the switch to the
"RUN"(l) position.
7. Push the choke button to the RUN” position.