!9GAS CONVERSION
Injectors table
BURNERS
NOMINAL
POWER
REDUCED
POWER
LP/PROPANE
11” (279.4mm)
W.C.P.
NATURAL GAS
4” (101.6mm)
W.C.P.
BTU/HR BTU/HR
Ø INJECTOR
[1/100 MM]
Ø INJECTOR
[1/100 MM]
Semirapid (SR)
7600
(LP/Propane Gas) 1800 78
8000
(Natural Gas) 1800 136
Dual (D)
Inner crown 2800
1
1100
1
47
3
80
3
Full burner 18000
2
6500
2
79 (x2)
4
135 (x2)
4
OR30 GAS GAS MODELS ONLY
Oven burner 14000 2400 109 190
Broil burner 11000 100 170
1 Power calculated only with inner crown operating
2 Power calculated with inner and outer crown operating
3 Inner crown injector
4 Outer crown injector
Replacing the cooktop burner injectors
Remove the pan supports, the burner caps and the flame spreaders.
Using a wrench substitute the nozzle injectors with those most
suitable for the kind of gas for which it is to be used.
Refit the flame spreaders, the burner caps and the pan supports.
The burners are designed so that no regulation of the primary air is
required.
Semi-rapid burner Dual burner
Inner crown injector
Inner crown injector
Outer crown injector