Installation Guide

10
BACKGUARD CONSIDERATIONS
z
Installations against non-combustible surfaces: you may install the range without a backguard or choose any of the three backguards.
z
Installations close to combustible surfaces (above the cooking surface): without a backguard, there must be a min. 6" (152mm) clearance.
z
Installations immediately against combustible surfaces (above the cooking surface): you must purchase and fit the Wall Mount High
Backguard High Shelf and Angled Vent Trim.
z
Non-combustible surfaces: as defined in ‘National Fuel Gas Code’ (ANSI Z223.1, Current Edition). Clearances from non-combustible materials
are not part of the ANSI Z21.1 scope and are not certified by UL. Clearancesofless than 6" (152mm) must be approved by the local codes
and/or by the local authority having jurisdiction.
Combustible
RANGE
RANGE MOUNT
LOW BACKGUARD
WALL MOUNT
HIGH BACKGUARD, LOW SHELF
WALL MOUNT
HIGH BACKGUARD, HIGH SHELF
BACKGUARD WIDTH
INCHES MM
30" models BGRV2-1230 BGRV2-3030 BGRV3-3030H 29 7/8 759
36" models BGRV2-1236 BGRV2-3036 BGRV3-3036H 3 5 7/ 8 911
48" models BGRV2-1248 BGRV2-3048 BGRV3-3048H 47 7/8 1216
Note: Backguards can be purchased separately.
All ranges come fitted with an Integral Vent
Trim only.
For more information on Backguard
installation, refer to the separate instructions
provided with your backguard. Backguard
Installation Instructions can also be
downloaded from our website, www.
fisherpaykel.com
Non-combustible
min. 6"
(152mm)
min. 1/2"
(13mm)
min. 30"
(762mm)
NO BACKGUARD HIGH THICK BACKGUARD WITH ANGLED TRIM
BGRV2-3030H, BGRV2-3036H, BGRV2-3048H
NO BACKGUARD CUSTOM BACKGUARD
made from non-combustible materials
LOW THIN BACKGUARD
BGRV2-1230, BGRV2-1236, BGRV2-1248
HIGH THIN BACKGUARD
BGRV2-3030, BGRV2-3036, BGRV2-3048
BACKGUARD OPTIONSWALL SURFACE