Installation Guide

9
E
H
CLEARANCE DIMENSIONS
30" MODELS 36" MODELS 48" MODELS
IN
MM
IN MM IN MM
A Minimum width of ventilation hood installed above range 30 762 36 914 48 1219
B Minimum vertical distance between countertop and cabinet extending above counter 18 457 18 457 18 457
C Minimum clearance from left and right edge of range to nearest vertical combustible surface 12 305 12 305 12 305
D Minimum clearance from cook surface to:
z
combustible surface centered above the cook surface
z
combustible covering for ventilation hood centered above the cook surface
z
non-combustible surface* centered above the cook surface
54
36
30
1372
914
762
54
36
30
1372
914
762
54
36
30
1372
914
762
E Maximum overall depth of overhead cabinetry 13 330 13 330 13 330
F Width of cabinetry opening 30 762 36 914 48 1219
G Maximum height from floor to countertop:
– for level counter
– with range levelling legs fully extended
35 3/4
36 3/4
908
933
35 3/4
36 3/4
908
933
35 3/4
36 3/4
908
933
H Maximum depth from wall to cabinetry face:
z
projecting control panel
z
flush control panel
25 3/8
27 11/16
644
703
25 3/8
27 11/16
644
703
25 3/8
27 11/16
644
703
*Non-combustible surfaces: as defined in ‘National Fuel Gas Code’ (ANSI Z223.1, Current Edition). Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and
are not certified by UL. Clearances of less than 6" (152mm) must be approved by the local codes and/or by the local authority having jurisdiction.
ISO
FRONT
Note:
z
The cooking surface must sit flush or
above the adjacent countertop level.
z
If the range is to be placed adjacent
to cabinets, the clearances shown are
required. The same clearances apply
to island installations.
z
The range can be placed in various
positions with respect to the cabinet
front, with the control panel either
flush or projecting, depending on the
cabinetry depth.
z
The electrical and gas supply should
be within the zones shown in the
following diagrams
z
Any openings in the wall behind the
range and in the floor under the range
must be sealed.
z
Always keep the appliance area clear
and free from combustible materials,
gasoline and other flammable vapors
and liquids.
z
Do not obstruct the flow of combustion
and ventilation air to the unit.
CLEARANCE DIMENSIONS–ALL MODELS
electrical
and gas
F
A
C C
B
G
D