4 8" P R O F E SSI O NAL R A N GE S & B AC KG UARDS — RHV3-484, RDV3-485GD, RDV3-488, BGRV2-1248, BGRV2-3048, BGRV3-3048H models PLANNING GUIDE
CONTENTS 48" Professional Range PAGE RHV3-484, RDV3-485GD, RDV3-488 in mm Key Design Decisions 5 20 Ventilation Requirements 6 21 Product & Cavity Dimensions 7 22 Clearance Dimensions 8 23 Cavity Preparation 9 24 Product & Cavity Dimensions 10 25 Clearance Dimensions 11 26 Cavity Preparation 12 27 Product & Cavity Dimensions 13 28 Clearance Dimensions 14 29 Cavity Preparation 15 30 48" Professional Range RHV3-484-N, RHV3-484-L 48" Professional Range RDV3-485GD-N, RDV3
CONTENTS (continued) 48" Professional Range Backguard BGRV2-1248 Product Dimensions PAGE 16 31 17 32 18 33 48" Professional Range Backguard BGRV2-3048 Product Dimensions 48" Professional Range Backguard BGRV3-3048H Product Dimensions
IMPERIAL
KEY DESIGN DECISIONS 48" Professional Range 1 2 3 INSTALL TYPE REAR SURFACE BACKGUARD OPTIONS Model no: RHV3-484, RDV3-486GD, RDV3-488 BGRV3-3048H ANGLED TRIM (Supplied with backguard) BGRV2-1248 MIN 6" CLEARANCE WALL COMBUSTIBLE HIGH THICK BACKGUARD WITH ANGLED TRIM NO BACKGUARD LOW THIN BACKGUARD BGRV2-3048 CUSTOM BACKGUARD* MIN 30" MAX 1/2" NON COMBUSTIBLE CUSTOM FABRICATED* BACKGUARD ISLAND HIGH THIN BACKGUARD *Fabricated from non combustible materials only NO BACKGUARD DATE: 17.
VENTILATION REQUIREMENTS 48" Professional Range 1 2 INSTALL TYPE HOOD SURROUND MATERIAL Model no: RHV3-484, RDV3-486GD, RDV3-488 Note: RGV3-366 illustrated but all dimensions apply to the above models Specifications MIN 19" MIN 19" Ventilation Unit Hood Blower Ventilation Unit MIN 30" MAX 42"* MIN 36" Hood Blower Wall Installation Minimum 19'' Deep x Unit Width Minimum 1100 CFM Island Installation Minimum 19'' Deep x Unit Width Minimum 1100 CFM Note: A suitable hood must be installed above the
PRODUCT & CAVITY DIMENSIONS 48" Professional Range - Dual Fuel/Induction B 47 7/8" Model no: RHV3-484 H Product Dimensions c 29 1/8" in a Height of range (from floor to cooktop, excluding grates and rear trim) min 35 3/4" max 36 3/4" B Overall width of range CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL 47 7/8" c Overall depth of range (excluding handle and dials) 29 1/8" d Depth from rear of chassis to cabinetry face - projecting 25 3/8" e Depth from rear of chassis to cabinetry
CLEARANCE DIMENSIONS 48" Professional Range - Dual Fuel/Induction C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE Model no: RHV3-484 F D MINIMUM CLEARANCE: COMBUSTIBLE SURFACE in Clearance Dimensions CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL a Minimum width of ventilation hood installed above range - not shown* 48' B Minimum vertical distance between cou
CAVITY PREPARATION 48" Professional Range - Dual Fuel/Induction Model no: RHV3-484 Specifications Oven Total Capacity 2.1 cu.ft. + 4.8 cu.ft Electrical Supply 120/240 VAC, 60Hz Service 50 amp circuit Max Current Draw LEFT SIDE OF CAVITY Receptacle 75 A 4-prong grounding type [NEMA 14-50P plug] Gas Connection 1 1/2" Natural Gas 6" to 9" W.C LP Propane 11" to 14" W.C Types FINAL POSITION OF RANGE AGAINST WALL REGULATOR* 1/2” NPT Minimum 5/8” dia.
PRODUCT & CAVITY DIMENSIONS 48" Professional Range - Dual Fuel B 47 7/8" Model no: RDV3-485GD H in Product Dimensions c 29 1/8" a Height of range (from floor to cooktop, excluding grates and rear trim) min 35 3/4" max 36 3/4" B Overall width of range CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL 47 7/8" c Overall depth of range (excluding handle and dials) 29 1/8" d Depth from rear of chassis to cabinetry face - projecting 25 3/8" e Depth from rear of chassis to cabinetry face -
CLEARANCE DIMENSIONS 48" Professional Range - Dual Fuel C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE Model no: RDV3-485GD F D MINIMUM CLEARANCE: COMBUSTIBLE SURFACE in Clearance Dimensions CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL a Minimum width of ventilation hood installed above range - not shown* 48' B Minimum vertical distance between countertop
CAVITY PREPARATION 48" Professional Range - Dual Fuel Model no: RDV3-485GD Specifications Oven Total Capacity 2.1 cu.ft + 4.8 cu.ft Electrical Supply 120/240 VAC, 60Hz Service 50 amp circuit Max Current Draw LEFT SIDE OF CAVITY Receptacle 44 A 4-prong grounding type [NEMA 14-50P plug] Gas Connection 1 1/2" Natural Gas 6" to 9" W.C LP Propane 11" to 14" W.C Types FINAL POSITION OF RANGE AGAINST WALL REGULATOR* 1/2” NPT Minimum 5/8” dia.
PRODUCT & CAVITY DIMENSIONS 48" Professional Range - Dual Fuel B 47 7/8" Model no: RDV3-488 H Product Dimensions c 29 1/8" in a Height of range (from floor to cooktop, excluding grates and rear trim) min 35 3/4" max 36 3/4" B Overall width of range CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL 47 7/8" c Overall depth of range (excluding handle and dials) 29 1/8" d Depth from rear of chassis to cabinetry face - projecting 25 3/8" e Depth from rear of chassis to cabinetry face - fl
CLEARANCE DIMENSIONS 48" Professional Range - Dual Fuel C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE Model no: RDV3-488 F D MINIMUM CLEARANCE: COMBUSTIBLE SURFACE in Clearance Dimensions CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL a Minimum width of ventilation hood installed above range - not shown* 48' B Minimum vertical distance between countertop an
CAVITY PREPARATION 48" Professional Range - Dual Fuel Model no: RDV3-488 Specifications Oven Total Capacity 2.1 cu.ft + 4.8 cu.ft Electrical Supply 120/240 VAC, 60Hz Service 50 amp circuit Max Current Draw LEFT SIDE OF CAVITY Receptacle 44 A 4-prong grounding type [NEMA 14-50P plug] Gas Connection 1 1/2" Natural Gas 6" to 9" W.C LP Propane 11" to 14" W.C Types FINAL POSITION OF RANGE AGAINST WALL REGULATOR* 1 1/2" 1/2” NPT Minimum 5/8” dia.
PRODUCT DIMENSIONS 48" Professional Range Backguard NOT TO SCALE BGRV2-1248 Model no: BGRV2-1248 Product Dimensions A Height of backguard above vent trim on range B Overall height of backguard c 47 7/8'' C Overall width of backguard D Overall depth of backguard DATUM : BACK OF PRODUCT in 10 3/8'' 15 15/16'' 47 7/8'' 1/2'' E Height of backguard below vent trim on range 5 9/16'' F Depth of backguard below vent trim on range 1/16'' RDV3-485GD (illustrated) PLAN VIEW DATUM : BACK OF PRODUCT d 1/2'
PRODUCT DIMENSIONS 48" Professional Range Backguard NOT TO SCALE BGRV2-3048 C 47 7/8" Model no: BGRV2-3048 DATUM : BACK OF PRODUCT Product Dimensions A Height of backguard above vent trim on range D F B Overall height of backguard 29 1/8" C Overall width of backguard 47 7/8" D Overall depth of backguard and racks 9 5/16" E Depth of backguard F Depth of racks G Width of racks RDV3-485GD (illustrated) H Distance from top of backguard to bottom of racks G I Distance from bottom of backguard t
PRODUCT DIMENSIONS 48" Professional Range Backguard with Angled Vent Trim NOT TO SCALE B 47 7/8" BGRV3-3048H Model no: BGRV3-3048H DATUM : BACK OF BACKGUARD Product Dimensions f A Overall height of backguard with angled vent trim c h B Overall width of backguard 47 7/8'' C Overall depth of backguard and racks 10 3/8'' D Height of backguard 26 1/2'' E Height of angled vent trim 3 1/2'' F Depth of angled vent trim 2 7/8'' G Depth of backguard RDV3-485GD (illustrated) 1 5/16''' i H Depth
METRIC
KEY DESIGN DECISIONS 48" Professional Range 1 2 3 INSTALL TYPE REAR SURFACE BACKGUARD OPTIONS Model no: RHV3-484, RDV3-486GD, RDV3-488 BGRV3-3048H ANGLED TRIM (Supplied with backguard) BGRV2-1248 MIN 152mm CLEARANCE WALL COMBUSTIBLE HIGH THICK BACKGUARD WITH ANGLED TRIM NO BACKGUARD LOW THIN BACKGUARD BGRV2-3048 CUSTOM BACKGUARD* MIN 762mm MAX 13mm NON COMBUSTIBLE CUSTOM FABRICATED* BACKGUARD ISLAND HIGH THIN BACKGUARD *Fabricated from non combustible materials only NO BACKGUARD DATE:
VENTILATION REQUIREMENTS 48" Professional Range 1 2 INSTALL TYPE HOOD SURROUND MATERIAL Model no: RDV3-485GD, RDV3-486GD, RDV3-486GL, RDV3-488 Note: RDV3-366 illustrated but all dimensions apply to the above models Specifications MIN 480mm MIN 480mm Ventilation Unit Hood Blower MIN 762mm MAX 1067mm* Ventilation Unit MIN 914mm Hood Blower Wall Installation Minimum 480mm Deep x Unit Width Minimum 1100 CFM Island Installation Minimum 480mm Deep x Unit Width Minimum 1100 CFM Note: A suitable hood m
PRODUCT & CAVITY DIMENSIONS 48" Professional Range - Dual Fuel/Induction B 1216 Model no: RHV3-484 H Product Dimensions c 740 a Height of range (from floor to cooktop, excluding grates and rear trim) B Overall width of range CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL u p p mm min 908 max 933 1216 c Overall depth of range (excluding handle and dials) 740 d Depth from rear of chassis to cabinetry face - projecting 644 e De
CLEARANCE DIMENSIONS 48" Professional Range - Dual Fuel/Induction C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE Model no: RHV3-484 F D CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL MINIMUM CLEARANCE: COMBUSTIBLE SURFACE Clearance Dimensions mm a Minimum width of ventilation hood installed above range - not shown* 1219 B Minimum vertical distance between co
CAVITY PREPARATION 48" Professional Range - Dual Fuel/Induction Model no: RHV3-484 Specifications Oven Total Capacity 60L + 136L Electrical Supply 120/240 VAC, 60Hz Service 50 amp circuit Max Current Draw LEFT SIDE OF CAVITY Receptacle 75 A 4-prong grounding type [NEMA 14-50P plug] Gas Connection 38mm Natural Gas 6" to 9" W.C LP Propane 11" to 14" W.C Types FINAL POSITION OF RANGE AGAINST WALL REGULATOR* 38mm 1/2” NPT Minimum 5/8” dia.
PRODUCT & CAVITY DIMENSIONS 48" Professional Range - Dual Fuel B 1216 Model no: RDV3-485GD H Product Dimensions c 740 a Height of range (from floor to cooktop, excluding grates and rear trim) B Overall width of range CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL u p p 1216 c Overall depth of range (excluding handle and dials) 740 d Depth from rear of chassis to cabinetry face - projecting 644 e Depth from rear of chassis to
CLEARANCE DIMENSIONS 48" Professional Range - Dual Fuel C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE Model no: RDV3-485GD F D CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL MINIMUM CLEARANCE: COMBUSTIBLE SURFACE Clearance Dimensions mm a Minimum width of ventilation hood installed above range - not shown* 1219 B Minimum vertical distance between countertop
CAVITY PREPARATION 48" Professional Range - Dual Fuel Model no: RDV3-485GD Specifications Oven Total Capacity 60L + 136L Electrical Supply 120/240 VAC, 60Hz Service Receptacle LEFT SIDE OF CAVITY 50 amp circuit 4-prong grounding type [NEMA 14-50P plug] Max Current Draw 44 A Gas Natural Gas 6" to 9" W.C LP Propane 11" to 14" W.C Types FINAL POSITION OF RANGE AGAINST WALL REGULATOR* 38mm Connection 1/2” NPT Minimum 5/8” dia. flex line *Regulator location may vary depending on model.
PRODUCT & CAVITY DIMENSIONS 48" Professional Range - Dual Fuel B 1216 Model no: RDV3-488 H Product Dimensions c 740 a Height of range (from floor to cooktop, excluding grates and rear trim) B Overall width of range CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL u p p mm min 908 max 933 1216 c Overall depth of range (excluding handle and dials) 740 d Depth from rear of chassis to cabinetry face - projecting 644 e Depth from r
CLEARANCE DIMENSIONS 48" Professional Range - Dual Fuel C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE Model no: RDV3-488 F D CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL MINIMUM CLEARANCE: COMBUSTIBLE SURFACE Clearance Dimensions mm a Minimum width of ventilation hood installed above range - not shown* 1219 B Minimum vertical distance between countertop a
CAVITY PREPARATION 48" Professional Range Model no: RDV3-488 Specifications Oven Total Capacity 60L + 136L Electrical Supply 120/240 VAC, 60Hz Service 50 amp circuit Max Current Draw LEFT SIDE OF CAVITY Receptacle 44 A 4-prong grounding type [NEMA 14-50P plug] Gas Connection 38mm Natural Gas 6" to 9" W.C LP Propane 11" to 14" W.C Types FINAL POSITION OF RANGE AGAINST WALL REGULATOR* 38mm 1/2” NPT Minimum 5/8” dia. flex line *Regulator location may vary depending on model.
PRODUCT DIMENSIONS 48" Professional Range Backguard NOT TO SCALE BGRV2-1248 Model no: BGRV2-1248 Product Dimensions c 1216 263 B Overall height of backguard 405 C Overall width of backguard 1216 D Overall depth of backguard DATUM : BACK OF PRODUCT mm A Height of backguard above vent trim on range 13 E Height of backguard below vent trim on range 142 F Depth of backguard below vent trim on range 1 RGV3-485GD/ RDV3-485GD (illustrated) PLAN VIEW DATUM : BACK OF PRODUCT c 1216 d 13 A 263
PRODUCT DIMENSIONS 48" Professional Range Backguard NOT TO SCALE BGRV2-3048 C 1216 Model no: BGRV2-3048 DATUM : BACK OF PRODUCT Product Dimensions D F 720 B Overall height of backguard 740 C Overall width of backguard 1216 D Overall depth of backguard and racks 237 E Depth of backguard RGV3-485GD/ RDV3-485GD (illustrated) G PLAN VIEW DATUM : BACK OF PRODUCT mm A Height of backguard above vent trim on range 13 F Depth of racks 224 G Width of racks 1153 H Distance from top of backguard
PRODUCT DIMENSIONS 48" Professional Range Backguard with Angled Vent Trim NOT TO SCALE B 1216 BGRV3-3048H Model no: BGRV3-3048H DATUM : BACK OF BACKGUARD Product Dimensions f c h 763 B Overall width of backguard 1216 C Overall depth of backguard and racks 264 D Height of backguard 673 E Height of angled vent trim RDV3-485GD (illustrated) 90 F Depth of angled vent trim 73 G Depth of backguard 33 i H Depth of racks 230 PLAN VIEW I Width of racks 1152 J Distance from top of backguard
IMPORTANT: The product dimensions and specifications apply at the date of issue. Under our policy of continuous product improvement, these dimensions and specifications may change at any time. Dimensions may vary by ±2mm (1/16"). Please read the installation guide for detailed information on installing the product or visit fisherpaykel.com.