INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES PRODUCT DATUM -------------------------------------------
CLEARANCE DIMENSIONS
48" Professional Range - Dual Fuel
0 5 10 20
inches
Model no:
RDV3-485GD
Clearance Dimensions
in
a Minimum width of ventilation hood installed above range
- not shown*
48'
B Minimum vertical distance between countertop and cabinet
extending above counter
18''
c Minimum clearance from left and right of range to nearest
vertical combustible surface
12''
d Minimum clearance from cooking surface to:
- combustible surface centered above the cooking surface
- combustible covering for ventilation hood centered above
the cooking surface
- non-combustible surface** centered above the cooking
surface
54''
6''
0''
e Maximum overall depth of overhead cabinetry
1''
f Distance from center of rear burner to rear of product
8 5/8"
*IMPORTANT NOTE: For full installation and clearance details please refer to
our installation manual.
**Non-combustible surfaces: as defined in ‘National Fuel Gas Code’ (ANSI
Z223.1, Current Edition). Clearances from non-combustible materials are not
part of the ANSI Z21.1 scope and are not certified by UL. Clearances of less
than 6" (152mm) must be approved by the local codes and/or by the local
authority having jurisdiction.
DATUM : FLOOR
FRONT VIEW PROFILE VIEW
DATUM :
TOP OF COUNTERTOP
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
PLAN VIEW
MINIMUM CLEARANCE:
COMBUSTIBLE SURFACE
MAXIMUM OVERALL DEPTH
OF OVERHEAD CABINETRY
MINIMUM CLEARANCE:
ADJACENT OVERHEAD CABINET
MINIMUM CLEARANCE:
NON-COMBUSTIBLE SURFACE
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
D
E
D
B
C
C
F
MINIMUM CLEARANCE:
VENTILATION HOOD
D