- Sanyo Fisher Co. INSTRUCTIONS MANUAL Multiplexer MPX-CD163, MPX-CD93

DISPLAY SET SETTINGS
Example 2: To set the automatic switching period for the main monitor.
Set cameras 1 to 8 to 2-second automatic switching displays.
Set camera 9 to 16 to 3-second automatic switching displays.
Note: The automatic switching display period for spot monitors can be set in the same way (when the setting conditions for each
camera are the same as for the main monitor).
Use the cursor button to select
SEQUENCE 1S”.
Use the setting button () to select
“INDIV.”, and then press the NEXT
button.
The SEQUENCE SET screen will be
displayed.
Use the cursor button to select the
MAIN MONITOR 1S setting, and
then press the setting buttons () to
change the setting to “INDIV.”.
INDIV. INTERVAL appears at the bottom
of the screen.
Use the cursor button to select
INDIV. INTERVAL and then press
the NEXT button.
The INDIVIDUAL INTERVAL screen will be
displayed.
1
(DISPLAY SET)
TITLE DOWN ¤
MULTI SCREEN NORMAL
SEQUENCE 1 S
MASK OFF
MAIN†SPOT1 OFF
DIGITAL CONNECTION OFF
COLOR LEVEL AUTO
(*:NEXT)
NEXT
2
(DISPLAY SET)
TITLE DOWN ¤
MULTI SCREEN NORMAL
SEQUENCE INDIV.*
MASK OFF
MAIN†SPOT1 OFF
DIGITAL CONNECTION OFF
COLOR LEVEL AUTO
(*:NEXT)
3
(SEQUENCE SET)
MAIN MONITOR INDIV.¤
SPOT MONITOR-1 1 S ¤
SPOT MONITOR-2 1 S ¤
SPOT MONITOR-3 1 S ¤
SPOT MONITOR-4 1 S ¤
QUAD 1 S
INDIV. INTERVAL *
(*:NEXT)
NEXT
4
(SEQUENCE SET)
MAIN MONITOR INDIV.¤
SPOT MONITOR-1 1 S ¤
SPOT MONITOR-2 1 S ¤
SPOT MONITOR-3 1 S ¤
SPOT MONITOR-4 1 S ¤
QUAD 1 S
INDIV. INTERVAL *
(*:NEXT)
Use the cursor button to select
01:1S, and then press the setting
buttons to change the setting to
2S”.
Automatic switching display at the
specified switching interval is enabled
when you have entered a switching period
for each camera.
With the same procedure:
Set 02 to 08 to 2 S.
Move the cursor to the right and set 09
to 16 to 3 S.
Press the BACK button.
The setting will then be completed.
Press the BACK button once more to
return to the MAIN MENU screen.
Press the MENU button.
The display will return to the camera image
display screen.
If the SEQUENCE button is then pressed,
the screen images will start switching
automatically according to the settings that
have been made.
DISPLAY SET-5
+
5
(INDIVIDUAL INTERVAL)
IN IN
01: 2 S 09: 3 S
02: 2 S 10: 3 S
03: 2 S 11: 3 S
04: 2 S 12: 3 S
05: 2 S 13: 3 S
06: 2 S 14: 3 S
07: 2 S 15: 3 S
08: 2 S 16: 3 S
(INDIVIDUAL INTERVAL)
IN IN
01: 1 S 09: 1 S
02: 1 S 10: 1 S
03: 1 S 11: 1 S
04: 1 S 12: 1 S
05: 1 S 13: 1 S
06: 1 S 14: 1 S
07: 1 S 15: 1 S
08: 1 S 16: 1 S
MENUBACK
6
DISPLAY SET-5
44
English