User Guide

Table Of Contents
427-0089-00-12 Version 180 August 2020 12
This document does not contain any export-controlled information.
Camera Installation
1.3.8 Sunshield
The camera includes a sunshield which should be used for any installation where the camera is
exposed to direct sunlight or precipitation, If the camera is mounted with the top mounting holes, the
sunshield is not used. Depending on the needs of the installation, the sunshield can be positioned in
the neutral (middle) position, or slightly forward or rearward. To change the position of the sunshield,
temporarily loosen the three 3 mm hex screws on top, slide the sunshield forward or backward, and
re-tighten the screws.
1.3.9 Removing the Cover
In order to access the electrical
connections and install the cables, it is
necessary to temporarily remove the top
cover of the camera housing. The top
cover of the camera is held in place with
four 3 mm hex screws. The screws are
accessible through slots in the
sunshield, so the sunshield does not
need to be removed from the top cover.
Use a 3 mm hex key to loosen the four
captive screws, exposing the
connections inside the camera
enclosure. There is a grounding wire
connected inside the case to the top
cover, as shown. If it (or any of the
grounding wires) is temporarily
disconnected during the installation, it
must be reconnected to ensure proper
grounding of the camera.
When replacing the cover, tighten the four 3 mm hex screws to 1.8 n-m (16.0 in-lbs).
Caution!
When replacing the cover, ensure that the ground wire between the cover and the camera body is
completely inside the o-ring groove. If the wire is pinched between the cover and body the camera
is not sealed against water ingress and can be damaged.
Figure 1-5: Sunshield Mounting
Cover mounting screws (x4)
Sunshield mounting screws (x3)
Figure 1-6: Cover Removed (Sunshield attached)
Cover mounting
screws (x4)