Basic Operation and Configuration
Perform IR NUC Calibration
This button causes the camera to perform a Non-Uniformity Correction operation (refer to
Image freezes momentarily, pg. 40).
Function
The FC-Series cameras may have additional features or functions which can be accessed
using an extra numeric function keypad. When the button is selected, the keypad changes
to a numeric keypad providing programmed functions (1 - 9). Select the back arrow to return
to the main keypad. Select the forward arrow to access additional functions (10 - 18).
The available functions are specific to different camera installations. It
is possible to create customized camera functions through a “macro”
interface which can be programmed through XML commands. Contact
FLIR Technical Support for information about the Nexus XML-Based
Control Interfaces.
Test File Transfer
This button causes a request for the camera to transfer a file as determined by the settings
on the Maintenance > Sensor > File Transfer page.
Analytics On/Off—FC-Series ID only
The FC-Series ID camera Intrusion Detection Analytics can be enabled or disabled from the
Live Video page. Detection area and tripwire alarms must be setup prior to use.
Refer to Analytics Page—FC-Series ID only, pg. 50.
De-Ice On/Off—Configuration dependent
This button manually turns the lens heater on or off. The heater, when turned on manually,
will run for approximately 2 hours unless turned off either by the user (De-Ice button) or the
thermostat control. Refer to Supplemental Lens Heater, pg. 7.
Web Session Timeout
The default camera web page session timeout setting is 20 minutes. That is, after logging in to the
camera web page, if 20 minutes pass without any user input or action, the camera web page session
expires and the camera automatically logs the user out of the web page. However, you can change