User Guide

Table Of Contents
427-0089-00-12 Version 180 August 2020 28
This document does not contain any export-controlled information.
Basic Operation and Configuration
In the lower right of the Live Video web page, under the frame rate selector, click Advanced and then
change the Web Session Timeout setting. To disable the timeout, select No.
The setting only applies while the Live Video page is open. Logging out, navigating to the Setup or
Maintenance menus, rebooting, or performing a power cycle resets the Web Session Timeout
setting to its default, 20 minutes.
2.4 Basic Camera Configuration
The following procedures describe how to do the most common bench test camera configuration
steps, such as setting the camera IP address and hostname and changing the user passwords.
Additional setup and configuration options required after the camera has been installed in its final
location are described after the basic steps are given, refer to Advanced Configuration, pg. 43.
2.4.1 Setup Menu
The Setup menu is used for GEO Settings (Latitude and Longitude location), Video setup, thermal
(IR) camera setup, and defining Video Analytics motion detection zones. For additional details, refer
to Setup Menu, pg. 43.
Adjustments to the IR settings should only be made by someone who has expertise with thermal
cameras and a thorough understanding of how the various settings affect the image. In most
installations, the only camera settings needed are available from the Web Control panel on the Live
Video page (Scene Presets, Polarity, Palettes, and AGC). Haphazard changes can lead to image
problems including a complete loss of video. Additional information is provided in IR Page—Thermal
Image Setup, pg. 47.
Click Advanced
Select timeout in minutes