User Guide

Table Of Contents
427-0089-00-12 Version 180 August 2020 64
This document does not contain any export-controlled information.
Advanced Configuration
If you select Digital input, digital analytics output over IP, type the RTSP URL for the
camera’s secondary video stream (ch1).
If the camera’s RTSP authentication is enabled, then select Is Authentication Required
and type a valid user and password.
Step 3 Click Apply.
For more information about using the trk-101-P, see the FLIR ioi HTML Edition Units User Guide.
Modules Menu
This section describes the OSD Page (OSD) page, and Alarm Manager Page page. With the settings
on the OSD page, it is possible to display text information (for example, camera name, date/time,
etc.) as an overlay on the IP video streams. Use the Alarm Manager page to define rules for camera
alarms from Video Analytics or GPIO.
OSD Page: Use the OSD page to turn on and configure the On Screen Display (OSD) options. It
might be desirable to display camera-related information as an overlay on the video.
The following information can be displayed:
Label—Under Text Mode, select which of the following is overlaid on the video:
The camera’s host name, configured on the LAN Settings Page page
A custom text string, configured using the Text parameter when Custom is selected
The camera’s friendly name, configured in the Product Info Menu
IP Address
Date
•Time
Firmware Version
For each OSD item, you can configure the State, Preset Location, Font Size, and Background
Color. For the date, you can also specify the Format as EU (DD/MM/YYYY) or US (MM/DD/YYYY).