User Guide

This document does not contain any export-controlled information.
Installation
22
427-0300-00-12 - Revision 110 - May 2021
2. On the View Settings Home Page, click System Settings, and make sure the Network page appears.
4. Click Static IP addressing and then manually specify the camera's Hostname, IP address, Netmask,
and Gateway.
You can also specify the DNS Mode, Name Servers, MTU (maximum transmission unit), and Ethernet
Speed.
5. Click Save. Applying any changes on the Network page requires reboot the camera.
2.7.2 Install and Test the Optional Wash Kit
As an optional accessory, FLIR recommends the Videotec line of wash kits for PTZ cameras, including
the WASPT0V5L5M00 washer pump, five-liter tank, five-meter delivery kit. For general information about
installing a Videotec wash kit, see the kit's instructions manual.
This section and this guide contain important information about installing the washer and using it
specifically with the DX-Series camera.
Connection of the board
Connect the following:
J9 terminal on the
washer pump control board
Camera's
14-pin terminal connector
CP pump activation (dry contact)
Alarm-Out A1 pin (3)
GCP GND pump activation (dry contact)
Alarm-Out A2 pin (4)
Pump installation
Caution
DX-608 camera model: Do not use antifreeze liquid in the washer tank. This camera model does not
have a silicon window protecting its germanium thermal camera lens. Using antifreeze liquid causes
irreparable damage to the germanium lens. In this case, add ethanol in a 20% solution.
Washer installation (DX-Series)
1. Cut the cables to size and either restore or make the connections to the positioning unit.
2. Shorten the semi-rigid washer pipe
(01) as needed. Unscrew the nut (02)
from the joint and slide it along the
pipe. Insert the end of the pipe into the
ogive (03).
3. Lock the nut to the coupling.