Product Manual
Table Of Contents
- 1 Disclaimers
- 2 Safety information
- 3 Notice to user
- 4 Customer help
- 5 Quick Start Guide
- 6 Description
- 7 Operation
- 7.1 Charging the battery
- 7.2 Turning on and turning off the camera
- 7.3 Saving an image
- 7.4 Recalling an image
- 7.5 Deleting an image
- 7.6 Deleting all images
- 7.7 Measuring a temperature using a spotmeter
- 7.8 Measuring the hottest temperature within an area
- 7.9 Measuring the coldest temperature within an area
- 7.10 Hiding measurement tools
- 7.11 Changing the color palette
- 7.12 Changing image mode
- 7.13 Changing the temperature scale mode
- 7.14 Setting the emissivity as a surface property
- 7.15 Setting the emissivity as a custom material
- 7.16 Changing the emissivity as a custom value
- 7.17 Changing the reflected apparent temperature
- 7.18 Changing the settings
- 7.19 Updating the camera
- 8 Technical data
- 9 Declaration of conformity
- 10 Cleaning the camera
- 11 Application examples
- 12 About FLIR Systems
- 13 Glossary
- 14 Thermographic measurement techniques
- 15 History of infrared technology
- 16 Theory of thermography
- 17 The measurement formula
- 18 Emissivity tables
Operation
7
2. On the toolbar, select Temperature scale
. This displays a toolbar.
3. On the toolbar, select one of the following:
• Auto
.
• Lock
.
7.14 Setting the emissivity as a surface property
7.14.1 General
To measure temperatures accurately, the camera must know what kind of surface you
are measuring. You can choose between the following surface properties:
• Matt.
• Semi-matt.
• Semi-glossy.
For more information about emissivity, see section 14 Thermographic measurement
techniques, page 32.
7.14.2 Procedure
Follow this procedure:
1. Push the center of the navigation pad. This displays a toolbar.
2. On the toolbar, select Settings
. This displays a dialog box.
3. In the dialog box, select Measurement parameters. This displays a dialog box.
4. In the dialog box, select Emissivity. This displays a dialog box.
5. In the dialog box, select one of the following:
• Matt.
• Semi-matt.
• Semi-glossy.
7.15 Setting the emissivity as a custom material
7.15.1 General
Instead of specifying a surface property as matt, semi-matt or semi-glossy, you can spec-
ify a custom material from a list of materials.
For more information about emissivity, see section 14 Thermographic measurement
techniques, page 32.
7.15.2 Procedure
Follow this procedure:
1. Push the center of the navigation pad. This displays a toolbar.
2. On the toolbar, select Settings
. This displays a dialog box.
3. In the dialog box, select Measurement parameters. This displays a dialog box.
4. In the dialog box, select Emissivity. This displays a dialog box.
5. In the dialog box, select Custom material. This displays a list of materials with known
emissivities.
6. In the list, select the material.
7.16 Changing the emissivity as a custom value
7.16.1 General
For very precise measurements, you may need to set the emissivity, instead of selecting
a surface property or a custom material. You also need to understand how emissivity and
reflectivity affect measurements, rather than just simply selecting a surface property.