Product Manual
Table Of Contents
- 1 Disclaimers
- 2 Safety information
- 3 Notice to user
- 4 Customer help
- 5 Quick Start Guide
- 6 Description
- 7 Operation
- 7.1 Charging the battery
- 7.2 Turning on and turning off the camera
- 7.3 Saving an image
- 7.4 Recalling an image
- 7.5 Deleting an image
- 7.6 Deleting all images
- 7.7 Measuring a temperature using a spotmeter
- 7.8 Measuring the hottest temperature within an area
- 7.9 Measuring the coldest temperature within an area
- 7.10 Hiding measurement tools
- 7.11 Changing the color palette
- 7.12 Changing image mode
- 7.13 Changing the temperature scale mode
- 7.14 Setting the emissivity as a surface property
- 7.15 Setting the emissivity as a custom material
- 7.16 Changing the emissivity as a custom value
- 7.17 Changing the reflected apparent temperature
- 7.18 Changing the settings
- 7.19 Updating the camera
- 8 Technical data
- 9 Declaration of conformity
- 10 Cleaning the camera
- 11 Application examples
- 12 About FLIR Systems
- 13 Glossary
- 14 Thermographic measurement techniques
- 15 History of infrared technology
- 16 Theory of thermography
- 17 The measurement formula
- 18 Emissivity tables
Thermographic measurement techniques14
3. Measure the radiation intensity (= apparent temperature) from the reflecting source
using the following settings:
• Emissivity: 1.0
• D
obj
: 0
You can measure the radiation intensity using one of the following two methods:
Figure 14.3 1 = Reflection source
Note
Using a thermocouple to measure reflected apparent temperature is not recommended for two impor-
tant reasons:
• A thermocouple does not measure radiation intensity
• A thermocouple requires a very good thermal contact to the surface, usually by gluing and covering
the sensor by a thermal isolator.
14.2.1.1.2 Method 2: Reflector method
Follow this procedure:
1. Crumble up a large piece of aluminum foil.
2. Uncrumble the aluminum foil and attach it to a piece of cardboard of the same size.
3. Put the piece of cardboard in front of the object you want to measure. Make sure that
the side with aluminum foil points to the camera.
4. Set the emissivity to 1.0.
5. Measure the apparent temperature of the aluminum foil and write it down.
Figure 14.4 Measuring the apparent temperature of the aluminum foil.
#T559828; r. AC/ 9610/10386; en-US