Product Manual
Table Of Contents
- 1 Disclaimers
- 2 Safety information
- 3 Notice to user
- 4 Customer help
- 5 Quick Start Guide
- 6 Description
- 7 Operation
- 7.1 Charging the battery
- 7.2 Turning on and turning off the camera
- 7.3 Saving an image
- 7.4 Recalling an image
- 7.5 Deleting an image
- 7.6 Deleting all images
- 7.7 Measuring a temperature using a spotmeter
- 7.8 Measuring the hottest temperature within an area
- 7.9 Measuring the coldest temperature within an area
- 7.10 Hiding measurement tools
- 7.11 Changing the color palette
- 7.12 Changing image mode
- 7.13 Changing the temperature scale mode
- 7.14 Setting the emissivity as a surface property
- 7.15 Setting the emissivity as a custom material
- 7.16 Changing the emissivity as a custom value
- 7.17 Changing the reflected apparent temperature
- 7.18 Changing the settings
- 7.19 Updating the camera
- 8 Technical data
- 9 Declaration of conformity
- 10 Cleaning the camera
- 11 Application examples
- 12 About FLIR Systems
- 13 Glossary
- 14 Thermographic measurement techniques
- 15 History of infrared technology
- 16 Theory of thermography
- 17 The measurement formula
- 18 Emissivity tables
Emissivity tables18
Table 18.1 T: Total spectrum; SW: 2–5 µm; LW: 8–14 µm, LLW: 6.5–20 µm; 1: Material; 2: Specification;
3:Temperature in °C; 4: Spectrum; 5: Emissivity: 6:Reference (continued)
1 2 3 4 5 6
Water layer >0.1 mm
thick
0–100 T 0.95–0.98 1
Water
snow
T 0.8 1
Water
snow –10 T 0.85 2
Wood 17
SW
0.98 5
Wood 19 LLW 0.962 8
Wood ground T 0.5–0.7 1
Wood pine, 4 different
samples
70
SW
0.67–0.75 9
Wood pine, 4 different
samples
70 LW 0.81–0.89 9
Wood planed 20 T 0.8–0.9 1
Wood planed oak 20 T 0.90 2
Wood planed oak 70
SW
0.77 9
Wood planed oak 70 LW 0.88 9
Wood plywood, smooth,
dry
36
SW
0.82 7
Wood plywood,
untreated
20
SW
0.83 6
Wood white, damp 20 T 0.7–0.8 1
Zinc
oxidized at 400°C
400 T 0.11 1
Zinc oxidized surface
1000–1200 T 0.50–0.60 1
Zinc polished 200–300 T 0.04–0.05 1
Zinc sheet 50 T 0.20 1