Information

1-800-283-5853 (US and Canada) • www.flukenetworks.com
26 27
Legacy Test Reference Cords, Adapters and Mandrels
Model Description
NF-MANDREL-50 Mandrel, 3 mm ber cable, 50 μm (1)
NF-MANDREL-625 Mandrel, 3 mm ber cable, 62.5 μm (1)
NFA-FC FC test adapters – set of two
NFA-LC LC test adapters – set of two
NFA-SC SC test adapters – set of two
NFA-ST ST test adapters – set of two
NFB1/2-LC/ST Kit of duplex MM 62.5 μm and 50 μm test cords with LC and ST adapters
NFK1-DPLX-FC Duplex MM 62.5 μm test reference cords for FC adapter – set of two
NFK1-DPLX-LC Duplex MM 62.5 μm test reference cords for LC adapter – set of two
NFK1-DPLX-SC Duplex MM 62.5 μm test reference cords for SC adapter – set of two
NFK1-DPLX-ST Duplex MM 62.5 μm test reference cords for ST adapter – set of two
NFK1-MANDREL-KIT Kit, mandrel, 3 mm ber cable, 50 μm and 62.5 μm
NFK2-DPLX-FC Duplex MM 50 μm test reference cords for FC adapter – set of two
NFK2-DPLX-LC Duplex MM 50 μm test reference cords for LC adapter – set of two
NFK2-DPLX-SC Duplex MM 50 μm test reference cords for SC adapter – set of two
NFK2-DPLX-ST Duplex MM 50 μm test reference cords for ST adapter – set of two
NFK3-DPLX-FC Duplex SM test reference cords for FC adapter – set of two
NFK3-DPLX-LC Duplex SM test reference cords for LC adapter – set of two
NFK3-DPLX-SC Duplex SM test reference cords for SC adapter – set of two
NFK3-DPLX-ST Duplex SM test reference cords for ST adapter – set of two
NFK1-SMPLX-SC Simplex MM 62.5 µm test reference cords for SC adapter – set of two
NFK1-SMPLX-LC Simplex MM 62.5 µm test reference cords for LC adapter – set of two
NFK1-SMPLX-ST Simplex MM 62.5 µm test reference cords for ST adapter – set of two
NFK2-SMPLX-SC Simplex MM 50 µm test reference cords for SC adapter – set of two
NFK2-SMPLX-LC Simplex MM 50 µm test reference cords for LC adapter – set of two
NFK2-SMPLX-ST Simplex MM 50 µm test reference cords for ST adapter – set of two
NFK3-SMPLX-SC Simplex SM test reference cords for SC adapter – set of two
NFK3-SMPLX-LC Simplex SM test reference cords for LC adapter – set of two
NFK3-SMPLX-ST Simplex SM test reference cords for ST adapter – set of two
Fiber QuickMap
-
Multimode Fiber Length and Distance to Fault
Fiber QuickMap quickly and efciently locates connections and breaks in multimode ber with the press
of one-button. By instantly (six second typical test time) providing distances to failures such as high-loss
and high-reectance incidents, it is the must-have troubleshooter for any technician who works with ber
in datacenters or campuses.
Locating faults like high loss connections or bad splices often requires a more expensive and complex
Optical Time Domain Reectometer (OTDR). The detail, documentation, certication and ease of use
provided by a Fluke Networks OTDR is exceptional, but is not always required for basic tests. Fiber Quick
Map uses reections to determine where db losses are occurring in just a few seconds, and lls the gap
between a Visual Fault Locator (VFL) and OTDR.
Quick set-up. Connect your ber and press the Test button. No lengthy set-up necessary
Find problems quickly. Six-second test time—no more blind troubleshooting that can waste hours
Locate high loss incidents or breaks—nd the most common causes of ber failure
See Key information on a large display; loss in db and distance in meters or feet
Visible in dark areas. Backlighted display turns off automatically
Tests 50/125µm and 62.5/125µm multimode ber up to 1,500 meters / 4,921 feet
Removable SC adapter is easily cleaned
Long battery life, 1,500 tests (typical) from 2 AA alkaline batteries
Rugged construction; vibration and drop tested to 1 meter
For singlemode ber - Use Fiber OneShot PRO
www.flukenetworks.com/fiber
Model Description Gold 1YR
FQM-MAIN Fiber QuickMap mainframe with carrying pouch GLD-FQM
FQM-KIT Fiber QuickMap Kit with SC/LC 50 μm Launch Fiber, Interchangeable LC Adapter and carrying pouch GLD-FQM
FTS900
Fiber QuickMap Kit with test reference cords (50 and 62.5 µm for both SC/SC and SC/LC), VisiFault
Visual Fault Locator and carrying case
GLD-FQM
FTS1000
Fiber QuickMap Troubleshooter Kit with test reference cords (50 and 62.5 µm for both SC/SC and SC/
LC), VisiFault Visual Fault Locator, and SimpliFiber Pro power meter and multimode source and case
GLD-FQM-FTK
FTS1100
Fiber QuickMap Troubleshooter Kit: Includes Fiber QuickMap, SC/SC and SC/LC (50 and 62.5 μm)
hybrid test reference cords cords, VisiFault VFL, SimpliFiber Pro power meter and multimode source,
FT500 FiberInspector Mini video microscope, and carrying case. (Available in the US only)
GLD-FQM-FTK
*For launch bers and accessories please see page 19
Fiber Cable Test Solutions
Fiber Cable Test Solutions
To learn more visit: www.flukenetworks.com/fiberquickmap