Instructions
Table Of Contents
- DSX-600 Users Manual
- LIMITED WARRANTY AND LIMITATION OF LIABILITY
- Contents
- List of Figures
- Chapter 1: Get Acquainted
- Overview of Features
- Contact Fluke Networks
- Register Your Product
- Technical Reference Handbook
- Additional Resources
- Supplements and Updated Manuals
- Kit Contents
- Symbols
- Safety Information
- Connectors, Keys, and LEDs
- About Link Interface Adapters
- AC Adapter and Battery
- Verify Operation
- How to Use the Touchscreen
- Change the Language
- Buttons to Do Tests and Save Results
- Overview of Memory Functions
- Options for Cable IDs
- About LinkWare Applications
- Chapter 2: Certify Twisted Pair Cabling
- Chapter 3: Certify Coaxial Cabling
- Chapter 4: Manage Test Results
- Chapter 5: Use Projects
- Chapter 6: Sync Projects with LinkWare™ Live
- Sign Up for a LinkWare Live Account
- How to See the Tester’s MAC Address
- Use LinkWare Live Through a Wired Ethernet Network
- Use LinkWare Live Through a Wi-Fi Network
- When You Cannot Sync a Deleted Project
- About the Asset Management Service
- Change the Network Settings
- Sign Your Tester Out of LinkWare Live
- Sign In to LinkWare Live from a Desktop or Mobile Device
- Import Projects from LinkWare Live into LinkWare PC
- Learn More About LinkWare Live
- Chapter 7: Maintenance
DSX-600 Series CableAnalyzer
Users Manual
56
Notes
Set the reference only after the testers are at an
ambient temperature between 10 °C and 40 °C
(50 °F and 104 °F).
The tester will not let you set the reference if the
patch cord is longer than 30 cm (12 in).
You can also set the reference with a 50 patch
cord
3 On the home screen, select a coaxial cable test.
4 On the home screen, tap TOOLS, then tap Set Reference.
5 On the SET REFERENCE screen tap TEST.
BK179.EPS
Figure 22. Reference Connections for Tests on Coaxial Cabling
DSX-CHA003
COAX ADAPTER
DSX-CHA003
COAX ADAPTER
Coaxial adapter
with F connector
adapter
30 cm (12 in) 75
coaxial patch cord
Coaxial adapter
with F connector
adapter