User Manual

SimpliFiber Pro Meter and Test Kits
Users Manual
14
Continuous Wave/2 kHz Modes
Press M to switch the source between continuous wave and
2 kHz modulated output signals.
Use continuous wave mode (CW/2 kHz LED on steady) if
making loss or power measurements with a meter other
than a SimpliFiber Pro meter.
Use the 2 kHz modulated output mode (CW/2 kHz LED
blinking) if locating fibers with a meter other than a
SimpliFiber Pro meter.
Auto Wavelength Mode
In auto wavelength mode the source’s signal includes an
identifier that tells the meter which wavelength to measure.
You can set the source to one wavelength or to
automatically switch between wavelengths. When the
source is automatically switching, the meter can
automatically measure loss or power at each wavelength in
one test. If you save the measurements, the meter saves all
wavelengths measured in one record.
To set the source to auto wavelength mode:
1
If the AUTO LED is not on, press A.
2
Press Z to manually switch wavelengths (one
wavelength LED is on) or to set the meter to
automatically switch between wavelengths
(wavelength LEDs blink alternately).
If the meter detects the auto wavelength signal, AUTO
appears on the display, and the meter automatically
measures at the correct wavelength.