User Manual

SimpliFiber Pro Meter and Test Kits
Users Manual
16
Cleaning Connector Ends
1
Touch the tip of a fiber optic solvent pen or swab
soaked in solvent to a lint-free dry wipe or fiber
cleaning card.
2
Wipe the connector end-face across the solvent spot,
then back and forth once across the dry area of the
wipe or card.
Note
Some connector styles, such as VF-45, may require a
different cleaning method.
Always cover unused connectors with protective caps. Clean
caps periodically with a swab or wipe and fiber optic solvent.
Changing the Connector Adapter
You can change the meter’s connector adapter to connect to
SC, ST, and LC fiber connectors. Additional adapter styles
may be available. Check the Fluke Networks web site for
updates.
WCaution
Cover all connectors with dust caps when not in
use.
Store extra connector adapters in the canisters
provided.
Do not touch the photodiode lens (see Figure 4).
Do not overtighten the adapter or use tools to
tighten the adapter.
To install a connector adapter, refer to Figure 4 and do the
following:
1
Locate the slot in the meter’s connector and the key on
the adapter ring.
2
Holding the adapter so it does not turn in the nut,
align the adapter's key with the meter connector's slot
and slide the adapter onto the connector.
3
Screw the nut onto the meter connector.