User Manual

Use caution when working with voltages
above 60 V dc or 30 V ac. Such voltages pose
a shock hazard.
Symbols
,
Application around and removal from hazardous live
conductors is permitted.
T Product is protected by double insulation.
W Risk of Danger. Important information. See Instruction Sheet.
X Hazardous voltage.
)
Conforms to relevant Canadian Standards Association
directives.
P Conforms to relevant European Union directives.
Safety Specifications
Category Rating: CAT III 1000 V and CAT IV 600 V per
EN61010-1, Pollution Degree 2
EMC: EN 61326-1, FCC for emission and immunity
): Tested to US and Canadian standards for compliance to
UL61010-1 and CAN/CSA C22.2 No. 101.1:2004
P: IEC 61010-1 2
nd
Edition IEC 61010-02-032
Electrical Specifications
Reference Conditions: 23 ± 5 °C, 20 to 75 % RH; conductor
centered in jaw opening; no DC component; no adjacent
conductor.
40 A Range 400 A Range
Measurement Range: 0.5 A to 40 A 5 A to 400 A
Output: 10 mV/A 1 mV/A
Accuracy:
45 Hz to 400 Hz
2 % + 0.015 A
2 % + 0.04 A
Phase Shift:
(45 Hz to 400 Hz)
0.5 A to 1 A
1 A to 5 A
5 A to 10 A
10 A to 20 A
20 A to 40 A
40 A to 400 A
Unspecified
4û
3û
3û
2û
NA
NA
NA
Unspecified
2û
2û
1.5û
Crest Factor: 3 3 to 300 A
2.5 to 400 A
Typical Bandwidth: 5 Hz to 10 kHz
Working Voltage: 1000 V ac rms, in compliance with
EN61010
Common Mode Voltage: 1000 V ac rms from earth ground, in
compliance with EN61010
Input Load Impedance (of host instrument): > 1 M in
parallel with up to 47 pF
Maximum Non-destructive Current: 1000 A
Duty Cycle: 0.5 A to 400 A continuous
Influence of Adjacent Conductor: < 9.0 mA/A
Influence of Conductor Position in Jaw Opening: ± 1.0 %
of reading + 0.05 A
General Specifications
Output Cable Length: 2.5 m
Maximum Conductor Size: 32 mm
Storage Temperature: -20 °C to 60 °C
Operating Temperature: 0 °C to 50 °C
Relative Humidity: 10 °C to 30 °C: 95 %
30 °C to 40 °C: 75 %
40 °C to 50 °C: 45 %
Temperature Coefficient: 0.01 % X (specified accuracy)/ °C
(< 18 °C or > 28 °C)
Altitude: Operating: 2000 m; 2000 m to 4000 m, derate
category rating to 1000 V CAT II/600 V CAT III, Non-operating:
12000 m
Dimensions: 150 x 70 x 30 mm
Weight: 114 g
Instrument Compatibility
The i400s is compatible with any Fluke Multimeter or any other
current measurement device that has the following features:
BNC or Banana inputs
Input accuracy of 2 % or better to take full advantage of
the accuracy of the Current Clamp.
Input impedance of > 1 M in parallel with up to 47 pF
Measurement Considerations
Center the conductor inside the Current Clamp jaw.
Make sure the clamp is perpendicular to the conductor.
For optimal reading, make sure the conductor is
positioned between the alignment marks on the jaws of
the Current Clamp.
Observe the following guidelines when making measurements:
Avoid taking measurements close to other current-
carrying conductors.
Operation
To use the i400s, refer to “Measurement Considerations” and
Figure 1:
1. If necessary, add a banana plug to the BNC connector
on the i400s.
2. Connect the clamp cable to the instrument. If using an
adapter, use the common and volts inputs of the meter
and switch it on.
3. Make sure the clamp and the measurement instrument
are set to the proper range. Use the range select
switch on the clamp.
4. The arrow on the top of the clamp must face towards
the load of the circuit.
5. Connect the current clamp jaws around the conductor
to be measured.
XW Warning
To avoid shock or personal injury, keep fingers
behind the tactile barrier, see Figure 1.
Single Current
Carrying
Conductor
Tactile Barrier
Alignment
Marks
Load Direction Arrow
Banana
Plug
Range
Switch
ayn03.eps
Figure 1. i400s Setup