Full Product Manual

OPERATION
14
Only operate generator on a level surface.
Always connect the nut and ground terminal on the frame to an appropriate ground source.
WARNING!
Generator must be properly grounded to prevent electrocution.
Turn fuel valve to the “ON” position. (See fig 11)
Turn the fuel selector to “GAS” position (See fig 12)
Slide the choke lever to the “Choke” position. (See fig 13) SKIP THIS IF THE ENGINE IS WARM OR HOT.
For electric start, Push and hold the engine START/ON/OFF switch in the “START” position. Do not hold the START/
ON/OFF switch in the “Start” position for more than 15 seconds. Allow 1 minute between starting attempts. (See fig14)
For manual start, turn the engine START/ON/OFF switch to the “ON” position. Pull the recoil handle (starter
cord) slowly until resistance is felt, then pull rapidly. (See fig 15)
Let engine run for several seconds and then gradually, as engine warms up, slide the choke lever towards the “RUN”
position until the choke is fully slid to the “RUN” position. (See fig 16)
How to Start Engine (See fig 10-16)
Fig 1
1
Fig 14 Electric Start
Fig 16
CHOKE RUN
CHOKE LEVER
CHOKE RUN
CHOKE LEVER
WAIT
5sec
Fig 13
SKIP THIS IF THE ENGINE IS
WARM OR HOT.
The ground terminal located on the back of the generator frame must always be used
to connect generator to a driven ground rod. Connect the ground terminal to the driven
ground rod with a No 8 AWG (American Wire Gauge) copper wire. The wire connects
to the terminal between the lock washer and nut. Tighten the nut securely to ensure
proper connection. Grounding the generator protects you from electric shock that
results from a build up of static electricity or undetected ground faults.
Fig 9
Grounding the Generator (See fig 9)
START
Fig 15 Recoil Start
START
When using gasoline
Place generator on a level surface. All electrical loads MUST be disconnected from generator.
When using LPG
Connect the gas pipe to the intake nozzle of regulator ; Open the valve of LPG bottle (See fig 10)
Turn the fuel selector to “LPG” position (See fig 12)
Slide the choke lever to the “Choke” position. (See fig 13) SKIP THIS IF THE ENGINE IS WARM OR HOT.
For electric start, Push and hold the engine START/ON/OFF switch in the “START” position. Do not hold the START/
ON/OFF switch in the “Start” position for more than 15 seconds. Allow 1 minute between starting attempts. (See fig14)
For manual start, turn the engine START/ON/OFF switch to the “ON” position. Pull the recoil handle (starter
cord) slowly until resistance is felt, then pull rapidly. (See fig 15)
Let engine run for several seconds and then gradually, as engine warms up, slide the choke lever towards the “RUN”
position until the choke is fully slid to the “RUN” position. (See fig 16)
Fig 10
Fig 1
2