3. Circuit breaker fuse rating must be above 50 A , and wire should be 2/6 or 3/6 copper.
4.
5. A wire-binding screw or stud used in the wire terminal should be 10 or larger.
1.
2.
Connecting to a 3 wire power supply cable electrical system
Warning!
1
7
VI.Counter Installation Instructions:
3.
lmportant-Save for the local electrical inspector's use.
To eliminate the risk of bums or fire by reaching over heated surface units,
cabinet storage space located above the surface units should be avoided. If
cabinet storage is to be provided, the risk can be reduced by installing a range
hood that projects horizontally a minimum of 5 inches beyond the bottom of the
cabinets.
An extension cord must not be used with this appliance. Such use may result
in a fire, electrical shock or other personal injury.
The electrical power to the cooktop must be shut o while line connections
are being made. Failure to do so could result in serious injury or death.
Minimum acceptable size of conductors should be no less than 10AWG,copper
only, and no less than167°F .