Refrigerator User Manual

2
Introduction
The display case are manufactured in two formats FHG 2L, 2 doors, and the FHG 3L, three doors.
There are also Multiplex options that are a combination of two FHG 2L cases to make a FHG 4L or a combination
of the FHG 2L and FHG 3L to make a FHG 5L.
Technical Specification.
Model 2 Door 3 Door 4 Door 5 Door
External Dimensions (m) Height (m) 2100 2100 2100 2100
Width (m) 1684 2463 3254 4035
Depth (m) 900 900 900 900
Internal Dimensions (m) Height (m) 1354 1354 1354 1354
Width (m) 1564 2343 3128 3907
Depth (m) 550 550 550 550
No. of Shelves 12 18 24 30
Shelf capacity (each) Kg 40 40 40 40
Door System Schott Schott Schott Schott
Refrigeration System
Compressor
Up to Aug
2004
Hitachi
FL200 DL
400v 3 phase
Hitachi FL200
DL
400v 3 phase
(x 2)
From Aug
2004
Hitachi
DS 183651
230v 1 phase
Hitachi
DS 183651
230v 1 phase
(x 2)
Hitachi
FL300DL
400 3 Phase
Hitachi
FL300DL
400 3 Phase
(x 2)
Refrigerant
R404A
2500 grms
R404A
3500 grms
R404A
2500 grms
(x 2)
R404A
2500 grms +
3500 grms
Vaporisation
Hot Gas Hot Gas Hot Gas Hot Gas
Defrost Type
Hot Gas and
Electric (1 kW)
Hot Gas and
Electric
( 1.5 kW)
Hot Gas and
Electric
(2.1kW)
Hot Gas and
Electric
(2.5 kW)
Electrical supply 230/1/50 400/3/50 230/1/50 X 2
400/3/50 +
230/50/1
Electrical Supply Capacity 16A 16A 16A 16A
Controller
Carel
PB00F0HB10
Carel
PB00F0HB10
Carel
PB00F0HB10
Carel
PB00F0HB10
Heat loads & Consumption
Lighting Watts 140 210 280 350
Door frame heaters Watts 266 380 522 646
Fan motors Watts 132 198 264 330
Compressor consumption Watts 2760
Compressor Duty Watts 2660
Compressor Current A 5.1