Wallmaster Service Manual (2010)

6
2010 PERFORMANCE DATA
Sleeve / Chassis Dimensions
27" Sleeve
Height (inches) 16 3/4 16 3/4 16 3/4
Width (inches)272727
Depth (inches) 16 3/4 16 3/4 16 3/4
Friedrich WSC
Sleeve
Fedders A
Sleeve
Fedders B Sleeve*
Sleeve Dimensions
WidthMax. Depth
WSD Sleeve 16 3/427 16 3/4237 1/2 9/16 17 1/4 27 1/415 5/16
Chassis 15 3/4 26 1/22122-----
Depth
with
Front
Minimum
Extension
Into Room
Minimum
Extension
Outside
Height
TTW Finished Hole
Height WidthDepth
Model
WALLMASTER
Specifications
WallMaster Heat Pump heating information (shown in red) indicates heat pump heating performance. WallMaster Electric Heat heating information (shown in red)
indicates electric heat strip performance. For WallMaster Heat Pump electric heating performance refer to corresponding WallMaster Electric Heat model.
Estar
Model
Cooling
Capacity Btu
Heating
Capacity Btu
Volts
Rated
Cooling
Amps Cooling Watts
Heating
Amps
Heating
Watts
Energy
Efciecy Ratio
EER
Moisture
Removal
Pints/HR
Room
Side Air
Circulation
CFM Sleeve
Net Weight
Lbs
WALLMASTER
Cool only
WS08C10A 7800 NA 115 7.1 788 NA NA 9.9 1.2 250 WSD 93
WS10C10A 9700 NA 115 10.0 1032 NA NA 9.4 2.4 257 WSD 103
WS12C10A 11900 NA 115 11.8 1266 NA NA 9.4 3.3 295 WSD 112
WS10C30A 9500/9200 NA 230/208 4.5/4.7 989/958 NA NA 9.6/9.6 1.5 300 WSD 101
WS13C30A 12600/12300 NA 230/208 6.3/6.7 1340/1309 NA NA 9.4/9.4 3.6 290 WSD 109
WS15C30A 14500/14500 NA 230/208 8.3/8.2 1706/1706 NA NA 8.5/8.5 4.2 290 WSD 119
Heat Pumps
WY09C33A 9300/9000 7300/7300 230/208 4.4/4.7 989/957 3.8/4.0 839/793 9.4/9.4 2.1 250 WSD 103
WY12C33A 12000/11800 9350/9200 230/208 6.1/6.4 1395/1372 4.8/5.1 1062/1010 8.6/8.6 2.6 275 WSD 111
Cool with Electric Heat
WE10C33A 9500/9200 11000/9100 230/208 4.5/4.7 989/958 16.0/14.7 3550/2950 9.6/9.6 1.5 300 WSD 121
WE13C33A 12600/12300 11000/9100 230/208 6.3/6.7 1340/1309 16.0/14.7 3550/2950 9.4/9.4 3.6 290 WSD 107
WE15C33A 14500/14500 11000/9100 230/208 8.3/8.8 1706/1706 16.0/14.7 3550/2950 8.5/8.5 4.2 290 WSD 116
DEFROST CONTROL: Initiated at 30°F (outdoor coil temperature for two
consecutive minutes) and terminated at 43°F (outdoor coil temperature). During
defrost, the compressor stops and the electric heat starts, then operates wit
h
the fan to maintain indoor comfort. The unit remains in electric heat mode.
DEFROST DRAIN: Drain automatically opens at approximately 50°F to prevent
condensate from freezing inside drain pan.
Note: all models will produce condensate. If condensate disposal is desired, an
optional drain kit is available.
As an partner, Friedrich Air Conditioning Co. has determined that the selected
(
) meet the guidelines for energy efficiency.
All models use
environmentally
friendly R-410A
refrigerant.
R-410A
*Rating Conditions: 80 degrees F, room air temp. & 50% relative humidity, with 95 degree F, outside air temp & 40% relative humidity, all systems use R410A
Dischar
ge
Temp
Suction
Temp
Liquid
Temp
Super
Heat
Evap
CFM
Motor
RPM
Locked
Rotor Amps
Charge in
OZ.
BREAKER
FUSE
60 Hertz
Amps
Sub-
Coolin
g
OPERATING
PRESSURES
ELECTRICAL RATINGS
R410A
Suction
Dischar
ge
Amps
Cool
Amps
Heat
WALLMASTER
EVAPORATOR AIR TEMP.
DEG. F
EVAPORATOR TEMP.
DEG. F
CONDENSER
TEMPERATU
DEG. F
RE
Discharge Air
Temp. Drop
F.
T(in)
T(out)
COOLING
PERFORMANCE
DATA*