Specification

Accessories information available
on the web at frigidaire.com
USA
10200 David Taylor Drive
Charlotte, NC 28262
1-800-FRIGIDAIRE
frigidaire.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
frigidaire.ca
FGEC3645P 12/13 © 2013 Electrolux Home Products, Inc.
Specifications
subject to change.
Built-In Cooktop
FGEC3645PS 36" Electric
Drop-In Induction / Electric Cooktops
(Callouts MUST be charted per individual model).
Professional / Gallery / Baseline
Built-In Cooktop Specifications
Product Shipping Weight (approx.) – 65 Lbs.
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz
AC only electrical supply with ground required on separate circuit
fused on both sides of line.
Connected Load (kW Rating) @ 240 / 208 Volts = 9.6 / 7.2 kW
Amps @ 240 / 208 Volts = 40.0 / 34.6 Amps
Recommended Circuit Breaker – 40 Amps
Always consult local and national electric codes.
Cooktop cutout height includes clearance needed beneath cooktop to
allow for armored cable and installation of junction box on back wall.
Position center of junction box 10" inward from right side of cooktop
cutout, and 12" down from underside of countertop.
Overhead cabinetry should not exceed a 13" maximum depth.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than 36-3/4".
Allow 30" minimum clearance between top of cooktop platform
and bottom of unprotected wood or metal overhead cabinet; or 24"
minimum clearance when bottom of wood or metal overhead cabinet
is protected by not less than 1/8" flame-retardant millboard covered
with not less than No. 28 MSG sheet steel, 0.015" stainless steel,
0.024" aluminum or 0.020" copper.
Allow 2" minimum clearance between rear edge of cutout and nearest
combustible surface (or backsplash) above countertop.
Allow 7-1/2" minimum required clearance from left edge of cooktop
to nearest combustible wall and 7-1/2" minimum from right edge of
cooktop to nearest combustible wall.
Installation of drawer beneath cooktop requires 4" minimum
clearance beneath countertop surface, and assured clearance for
electrical installation.
To reduce risk of fire when using overhead cabinetry, install
range hood that projects horizontally a recommended minimum
of 5" beyond bottom of cabinets.
Electric Built-In Cooktop model FGEC3645P is approved to be
used over any Frigidaire® Electric Single Wall Oven. (Refer to
Electric Cooktop Installation Over 30" / 27" Electric Single Wall Oven
Specifications page on web.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
Granite Countertop Installation Kit – (PN # 903061-9010).
Product Dimensions
Required Clearances
A - Width B - Depth C - Height G (min.) H (min.) I (min.) J (min.)
36-3/4" 21-3/8" 2-5/8" 2" 7-1/2" 7-1/2" 2-1/2"
Product Cutout Dimensions
K - Cabinet Opening Width
(min.)
Utility Connection Locations
D - Width (min. - max.) E - Depth (min. - max.) F - Height (min.)* Power Supply
35-5/8" - 36-1/8" 20-1/4" - 20-1/2"
5" 36-3/4" Right Rear