24" ELECTRIC RANGE INSTALLATION INSTRUCTIONS
Three Conductor Wire Connection to Range
If local codes permit connection of the frame grounding
conductor to the neutral wire of the copper power supply
cord (see Figure 8):
1. Remove the screws from the access plate at the
lower right end of the rear cover to expose range
terminal connection block.
2. Using the nuts supplied in the literature package,
connect the neutral of the copper power supply cord
to the center silver-colored terminal of the terminal
block, and connect the other wires to the outer
terminals. Match wires and terminals by color (red
wires connected to the right terminal, black wires
connected to the left terminal) (see Figure 8).
3. Replace the terminal cover and replace the screws.
Figure 8
Silver Colored
Terminal
1 1/8" (2.9 cm)
Dia. Direct
Connection
Hole. Punch Out
Knockout for 1 3/8"
(3.5 cm) Dia. Cord
Kit Hole.
To 240 V
Receptacle
A User Supplied
Strain-relief Must
Be Installed at
This Location.
Black
Wire
Terminal
Block
Grounding
Strap
Red
Wire
Neutral
(White Wire)
Cord
Mounting
Plate
Four Conductor Wire Connection to Range
Where local codes does NOT permit connection of the
frame grounding conductor to the neutral wire of the
copper power supply cord (see Figure 9):
1. Remove the screws from the access plate at the
lower right end of the rear cover to expose range
terminal connection block.
2. Remove the grounding strap from the terminal block
and from the appliance frame.
3. Using the nuts supplied with the literature package,
connect the ground wire (green) of the copper power
supply cord to the frame of the appliance with the
ground screw, using the hole in the frame where the
ground strap was removed (see Figure 9).
4. Connect the neutral of the copper power supply cord
to the center silver-colored terminal of the terminal
block, and connect the other wires to the outer
terminals. Match wires and terminals by color (red
wires connected to the right terminal, black wires
connected to the left terminal).
5. Replace the terminal cover and replace the screws.
Terminal Block
Silver Colored
Terminal
Ground (Bare
Copper Wire)
Red Wire
Neutral
(White Wire)
To 240 V
Receptacle
A User Supplied
Strain-relief Must
Be Installed at
This Location
Black
Wire
1 1/8" (2.9cm)
Dia. Direct
Connection
Hole. Punch
Out Knockout
for 1 3/8"
(3.5cm) Dia.
Cord Kit Hole.
NOTE: Be sure to remove the
supplied grounding strap.
Figure 9