Installation Instructions

6
24" ELECTRIC RANGE INSTALLATION INSTRUCTIONS
Direct Electrical Connection to the Circuit Breaker,
Fuse Box or Junction Box
If the appliance is connected directly to the circuit
breaker, fuse box or junction box, use exible, armored
or nonmetallic sheathed copper cable (with grounding
wire). Supply a U.L. listed strain-relief at each end of
the cable. At the appliance end, the cable goes through
the Direct Connection Hole (see Figure 9) on the Cord
Mounting Plate. Wire sizes (copper wire only) and
connections must conform to the rating of the appliance.
Where local codes permit connecting the appliance-
grounding conductor to the neutral (white) wire (see
Figure 10):
1. Be sure that no power is supplied on the cable from
residence.
2. Follow instructions on previous page for Four
Conductor Wire Connection to Range (Fig. 9).
3. In the circuit breaker, fuse box or junction box (Fig. 10):
a) Connect the green (or bare copper) wire, the white
appliance cable wire, and the neutral (white) wire
together.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
Figure 10
3-Wire (Grounded Neutral) Electrical System
(Example: Junction Box)
Cable from Residence
Junction
Box
White Wire
U.L.-listed Conduit
Connector (or CSA
listed)
Green
(or Bare
Copper) Wire
Red
Wires
Neutral
(white) Wire
Black
Wires
NOTE: Be sure to connect
the supplied ground strap
to the terminal block.
Cable from
Appliance
Where local codes DO NOT permit connecting the
appliance-grounding conductor to the neutral (white)
wire, or if connecting to 4-wire electrical system (see
Figure 11):
1. Be sure that no power is supplied on the cable from
residence.
2. Follow instructions on previous page for Four
Conductor Wire Connection to Range (Fig. 9).
3. In the circuit breaker, fuse box or junction box (Fig.
11):
a) Connect the white appliance cable wire to the
neutral (white) wire.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
d) Connect the green (or bare copper) grounding wire
to the grounding wire of the circuit breaker, fuse
box or junction box.
Figure 11
4-Wire Electrical System
(Example: Junction Box)
NOTE: Be sure to remove
the supplied grounding
strap.
U.L.-listed Conduit
Connector (or CSA
listed)
Cable from
Residence
Black
Wires
Junction
Box
White Wire
Cable from
Appliance
Green (or
Bare Copper)
Wire
Red
Wires
White Wire
Green (or Bare
Copper) Wire