Installation Instructions

6
96”
(244cm)
max.
33”
(84cm)
min.
INSTALLATION REQUIREMENTS
Use only 4 inch (102 mm) diameter rigid or exible metal duct and approved
vent hood which has a swing-out damper(s) that open when the dryer is in
operation. When the dryer stops, the dampers automatically close to prevent
drafts and the entrance of insects and rodents. To avoid restricting the outlet,
maintain a minimum of 12 inches (30.5 cm) clearance between the vent hood
and the ground or any other obstruction.
Correct
Incorrect
NOTE
For installations requiring a longer drain hose, have
a quali ed technician install a longer drain hose
(according to your model number) available from an
authorized parts distributor. For drain systems in the
oor, install a syphon break kit available from your local
hardware store.
Exhaust system requirements
If your present system is made up of plastic duct or metal foil duct, replace it
with a rigid or semi-rigid metal duct. Also, ensure the present duct is free of
any lint prior to installing dryer duct.
The following are speci c requirements for proper and safe opera-
tion of your dryer.
WARNING
FIRE HAZARD
Failure to follow these instructions can create excessive drying times and
re hazards.
WARNING
FIRE HAZARD
Do not install a clothes dryer with exible plastic or metal foil venting
materials. Flexible venting materials are known to collapse, be easily
crushed and trap lint. These conditions will obstruct clothes dryer air ow
and increase the risk of re.
Drain system requirements
1 Drain capable of eliminating 17 gals (64.3 L) per
minute.
2 A standpipe diameter of 1-1/4 in. (3.18 cm)
minimum.
3 The standpipe height above the oor should be:
Minimum height: 33 in. (84 cm)
Maximum height: 96 in. (244 cm)