Installation Guide

5
INSTALLATION REQUIREMENTS
NOTE
For installations requiring a longer drain hose, have
a quali ed technician install a longer drain hose
(according to your model number) available from an
authorized parts distributor. For drain systems in the
oor, install a syphon break kit available from your local
hardware store.
Installation in a Recess or Closet
If washer and dryer are installed in the same closet, door
ventilation is required: A minimum of 120 square inches
(774.2 cm²) of opening, equally divided at the top and
bottom of the door, is required. Louvered openings should
be located 3 inches (7.6 cm) from bottom and top of
door. Air openings are required to be unobstructed when
a door is installed. A louvered door with equivalent air
openings for the full length of the door is acceptable.
60 sq. in.
(387.1cm²)
3”
(7.6cm)
60 sq. in.
(387.1cm²)
3”
(7.6cm)
closet door
Drain system requirements
1 Drain capable of eliminating 17 gals (64.3 L) per
minute.
2 A standpipe diameter of 1-1/4 in. (3.18 cm)
minimum.
3 The standpipe height above the oor should be:
Minimum height: 36 in. (91 cm)
Maximum height: 96 in. (244 cm)
96”
(244 cm)
max.
36”
(91 cm)
min.