Spec Sheet

INSTALLATION SPECIFICATIONS
Product Shipping Weight (approx.) – 157 Lbs.
An electrical supply with grounded three-prong receptacle is required.
The power supply circuit must be installed in accordance with current edition
of National Electrical Code (ANSI/NFPA 70) and local codes & ordinances.
(Do not use same circuit as dryer.)
Voltage Rating – 120V / 60 Hz
Amps @ 120 Volts = 8.0 Amps
Equipped with 120V 3-wire power supply cord, approx. 70-1/2" long.
Always consult local and national electric & plumbing codes.
To maximize detergent effectiveness, ambient temperature should never be
below 60° F.
Washer installation requires 1" minimum installation clearance on each side
of unit and 6" minimum at back. To achieve 6" minimum rear clearance
when installed with dryer, dryer MUST use 90° quick-turn vent elbow. Closet
installation requires 2" minimum clearance between front of unit and vented
door. Door MUST be vented with 120 sq. in. minimum louvered opening,
equally divided, located 3" from top and bottom of door. A louvered door
with equivalent air openings for full-length of door is acceptable. Air openings
MUST remain unobstructed with door installed. (For additional installation
details, refer to Product Installation Guide on web.)
Do NOT install in area exposed to dripping water or outdoor weather
conditions; or where gasoline or other flammables, including automobiles,
are kept or stored.
Floor MUST be solid with 1" maximum slope. To minimize vibration or
movement, reinforcement of floor may be necessary. Do NOT install on
carpeted surface.
Leveling legs supplied to level unit properly and reduce excessive noise and
vibration.
H/C water faucets MUST be installed within 42" of washer’s water inlet and
MUST be 3/4" with threading for laundry hose connection to connect to 48"
inlet hoses.
Water pressure MUST be between 30 and 120 psi with NOT more than 10 psi
pressure difference between hot and cold.
Drain standpipe requires diameter of 1-1/4" min. and height of 39" min. /
96" max. above floor, capable of eliminating 17 gallons per minute. Attached
59" drain hose can reach 74"-high standpipe. For higher standpipe, optional
Drain Hose Extension Kit available.
Specifications subject to change. Accessories information available on the web at frigidaire.ca
Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes.
Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.ca.
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
frigidaire.ca FFTW4120S 06/18
© 2018 Electrolux Major Appliances, NA
Front
Side
Top Load Laundry - Washer (S Models)
Frigidaire Baseline
Vented door
6"
min. 2"
min.
Side
60"
sq.
in.
min.
3"
60"
sq.
in.
min.
3"
1"
min. 1"
min.
24"
min.
Front
Recess or Closet Installation
Washer installation requires 1" minimum installation
clearance on each side of unit and 6" minimum at
back. To achieve 6"
minimum rear clearance when
installed with dryer, dryer MUST use 90° quick-turn
vent elbow. Closet installation requires 2"
minimum
clearance between front of unit and vented door. Door
MUST be vented with 120 sq.
in. minimum louvered
opening, equally divided, located 3" from top and
bottom of door. A louvered door with equivalent air
openings for full-length of door is acceptable. Air
openings MUST remain unobstructed with door
installed. For additional installation details, refer
to Product Installation Guide on web.
27"
59"
29"
38
1
/2"
44
1
/4"
H/C Water
inlets (rear) -
48" hose
length
Drain hose
retention
clamp (rear)
59" Hose
length
beyond
clamp
120V Power
cord (rear) -
70
1
/2" long
FFTW4120SW
TOP LOAD WASHER
4.7 CU. FT. I.E.C.