Dimensions Guide
Specifications
subject to change.
Front
29
7
/8"
48"
max.
30" min.
13"
max.
25"
24"
Minimum
1" clearance
required
to nearest
combustible
wall on
either side
of range
above 36"
height
30"
6"
C
L
22"
11"
36"
stand.
30"
min.*
Wall
18"
min.
18"
min.
*Note: 30" minimum clearance between top of cooking
surface and bottom of unprotected wood or metal
overhead cabinet; or 24" minimum clearance when
bottom of wood or metal overhead cabinet is protected
by not less than 1/4" flame-retardant millboard covered
with not less than No. 28 MSG sheet steel, 0.015"
stainless steel, 0.024" aluminum or 0.020" copper.
0" clearance is minimum for rear of range. Follow all
dimension requirements provided above to prevent
property damage, potential fire hazard, and incorrect
countertop and cabinet cuts.
Side
49"
25
3
/
4
"
Power cord location
(middle bottom rear*)
*when viewed from front
29
1
/4"
36"
(Adjustable
to
±
1
/8")
Shaded area allows for flush-to-wall
installation of rear wall electrical
outlet. (All dimensions for outlet
location are maximum.)
2
5
/8" for warmer drawer models or
3
1
/2" for storage drawer models
Note: Overall
product dimensions
are model specific
and may vary slightly
from illustration. Refer
to model’s product
specifications for
actual dimensions.
30" Electric Freestanding Ranges (Storage or Warmer Drawer)
Frigidaire Gallery
USA
•
10200 David Taylor Drive
•
Charlotte, NC 28262
•
1-800-FRIGIDAIRE
•
frigidaire.com
CANADA
•
5855 Terry Fox Way
•
Mississauga, ON L5V 3E4
•
1-800-265-8352
•
frigidaire.ca
FGEF3059T 05/17 © 2017 Electrolux Home Products, Inc.
Freestanding Ranges
FGEF3059T D/ F 30" Electric
Freestanding Range Specifications
•
Product Shipping Weight (approx.) – 185 Lbs.
•
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz,
fused on both sides of line with ground.
•
Connected Load (kW Rating) @ 240 / 208 Volts = 13.0 / 10.0 kW
•
Always consult local and national electric codes.
•
Make sure wall coverings around range can withstand heat generated
by range.
•
Floor beneath range MUST be solid and level.
•
Overhead cabinetry should not exceed a 13" maximum depth.
•
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum
width of appliance.
•
Range can be installed flush to wall with 0" minimum rear clearance.
•
Minimum 1" clearance required from edge of rangetop to nearest
combustible wall on either side of range above 36" height.
•
Allow 30" minimum clearance between top of cooking surface and
bottom of unprotected wood or metal overhead cabinet; or 24"
minimum clearance when bottom of wood or metal overhead cabinet
is protected by not less than 1/4" flame retardant millboard covered
with not less than No. 28 MGS sheet steel, 0.015" stainless steel,
0.024" aluminum or 0.020" copper.
•
To reduce risk of fire when using overhead cabinetry, install
range hood that projects horizontally a recommended minimum
of 5" beyond bottom of cabinets.
•
Follow all dimension requirements provided to prevent property
damage, potential fire hazard, and incorrect countertop and
cabinet cuts.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.