IMPORTANT
Make sure the water line tubing goes
through the hole at the top of the
dispenser pocket. There is also a metal
wrap on the tubing to prevent damage
from the hinge rubbing against it. This
needs to be fixed back around the tube
in the proper location upon reinstallation
(just as long as the tube is protected
from the hinge).
11
DOOR REMOVAL
Lower Hinge Removal
Once both doors are in place, ensure they
are aligned with each other and level
(Reference INSTALLATION for more de-
tails), and replace the top hinge cover.
8. To reinstall the doors, reverse
the procedure.
7. In certain circumstances, you may need
to remove the lower hinges for clearance
purposes. To gain access to the lower
hinges, first extend the Custom-Flex
Temp Drawer. Unscrew the 3 lower hinge
screws and slide the hinge inward.
To remove the Custom-Flex
Temp Drawer
1. Fully open the drawer.
2. Remove the basket from the drawer.
3. Unsnap the 4 cable ties by pressing
clip sides together and pushing
them through the opening.
4. Remove the screw and the retaining
clip and disconnect the harness
NOTE
When reinserting the water tube and
replacing the top hinge cover, carefully