Manual

CONNECT WIRING INSTALL HOOD
WARNING: To reduce the risk of electric shock,
make sure power is switched off at the service
panel. Lock ortag service panel to prevent power
from being switched on accidentally.
HOUSE
WIRING
(120 VAC)
CARDBOARD
protect
cooktop)
r_ Connect House to hood. Use of
Wiring (120 VAC)
a
piece
Cardboard to protect the cooktop, if necessary.
GREEN
GROUND
SCREW
[_ Connect house black to hood black wire, house white to hood
white wire, and house ground under Green Ground Screw.
Securely tighten cable clamp onto house wiring.
KEYHOLE (4) MOUNTING SCREW (4)
[_ Hang hood from (4) Mounting Screws. Slide hood towards
wall until mounting screws are engaged in narrow end of (4)
Keyholes. Tighten mounting screws securely. A long
screwdriver works best.
[_ Replace bottom cover.
DUCT
TAPE
[-_ Connect ductwork to hood. Use Duct Tape to make joints
secure and air tight.
PAR20,
50W MAX.
HALOGEN
BULB (2)
- or-
R16,
40W MAX.
INCANDESCENT
BULB (2)
r_ install PAR20, 50 W Maximum Bulbs R16,
(2) Halogen
or
(2)
40 W Maximum Incandescent Bulbs. Purchase bulbs
separately.
CAUTION: Bulbs may be hot! Refer to bulb packag-
ing for further information.
r_ filters, turn at service and test for
Replace
on
power panel,
proper operation.