System monitoring
General Where no special device model is present, the inverter is fitted with WLAN-compatible Fro-
nius Datamanager 2.0 system monitoring as standard.
Among other things, system monitoring includes the following functions:
- Own web page displaying current data and a wide range of different setting options
- Option of connecting directly to Fronius Solar.web
- Automatic sending of service messages by SMS or e-mail in the event of a fault
- Internet connection via WLAN or LAN
- Option of controlling the inverter by specifying power limit values, minimum or maxi-
mum running times or target running times
- Control of the inverter via Modbus (tcp / rtu)
- Assignment of control priorities
- Control of the inverter by means of connected meters (Fronius Smart Meter or S0 me-
ter)
- Control of the inverter via a ripple control signal recipient (e.g. specification of reactive
power or effective power)
- Dynamic power reduction, taking self-consumption into account
Further information on Fronius Datamanager 2.0 can be found online in the Fronius Data-
manager 2.0 operating instructions.
Fronius Dataman-
ager during the
night or when the
available DC volt-
age is insufficient
The Night Mode parameter under "Display Settings" in the Setup menu is preset to OFF in
the factory.
For this reason the Fronius Datamanager cannot be accessed during the night or when the
available DC voltage is insufficient.
To nevertheless activate the Fronius Datamanager, switch the inverter off and on again at
the mains and press any key on the inverter display within 90 seconds.
See also the chapters on "The Setup menu items", "Display settings" (Night Mode).
Starting for the
first time
When starting Fronius Datamanager 2.0 for the first time,
- the Fronius Datamanager 2.0 plug-in card must be installed in the inverter,
or
- there must be a Fronius Datamanager Box 2.0 in the Fronius Solar Net ring.
IMPORTANT! In order to establish a connection to Fronius Datamanager 2.0, the end de-
vice in question (e.g. laptop, tablet, etc.) must be set up as follows:
- "Obtain IP address automatically (DHCP)" must be activated
NOTE! Starting the Fronius Datamanager 2.0 for the first time can be made sig-
nificantly easier with the aid of the Fronius Solar.web App.
The Fronius Solar.web App is available in the relevant App store.
NOTE! If the photovoltaic system has only one inverter, steps 1 and 2 below can
be skipped. In this case, starting for the first time will commence with step 3.