Product Manual

16
Connect inverter with Fronius Datamanager 2.0 or Fronius Datamanager Box 2.0 to
the Fronius Solar Net
When networking several inverters together in Fronius Solar Net:
Set the Fronius Solar Net master / slave switch on the Fronius Datamanager 2.0 plug-
in card correctly
- One inverter with Fronius Datamanager 2.0 = master
- All other inverters with Fronius Datamanager 2.0 = slave (the LEDs on the Fronius
Datamanager 2.0 plug-in cards are not illuminated)
Switch the device into service mode
- Activate the WLAN access point via the Setup menu on the inverter
The inverter establishes the WLAN access point. The WLAN access point remains open
for 1 hour.
The Setup wizard start page is displayed.
Installation using the Solar.web App Installation using a web browser
Download the Fronius Solar.web App
Run the Fronius Solar.web App
Connect the end device to the WLAN
access point
SSID = Fronius_240.xxxxx (5-8 dig-
its)
- Search for a network with the
name "Fronius_240.xxxxx"
- Establish a connection to this
network
- Enter password 12345678
(or connect the end device and invert-
er using an Ethernet cable)
Entry in browser:
http://datamanager
or
192.168.250.181 (IP address for
WLAN connection)
or
169.254.0.180 (IP address for LAN
connection)
1
2
3
Stand by
WiFi Access Point
DATCOM
USB
Clock
4
5
4
5