Warning message Remarks
W033: Speed reduction
The on "W034: "Speed reduction" programmed digital
input was opened. Delay 1 s.
W034: Dryer
The on "W034: Dryer" progr
opened.-
no delay.
W036: Condensate drain
The on "W036: "Condensate drain" programmed
tal input was closed.
W037: Air filter
The on "W037: "Air filter" programmed digital input
was closed. Monitoring starts after 15 minutes. Tri
gering of warning without delay.
W038: Oil/oil filter
The on "W038: "Oil/oil filter" programmed dig
was closed. Monitoring starts after 15 minutes. Tri
gering of warning without delay.
W039: Oil separator
The on "W039: "Oil separator" programmed digital
input was closed. Monitoring starts after 15 minutes.
Triggering of warning without
W044: Extension module
At least one of the configured MK200 expansion mo
ules is not answering (possible addresses 8 to 30).
W045:
I/O-Module (Add.1)
The analogue output module on address 1 does not
respond. This monitoring is only active
has been activated.
W046:
I/O-Module (Add.2)
The LLC module on address 2 does not respond. This
monitoring is only active in LLC master operation du
ing digital control of the LLC slave.
W048:
I/O-Module (Add.4)
The expansion
spond. This monitoring is only active, if this module
has been selected.
W049:
I/O-Module (Add.5)
The expansion module on address 5 does not r
spond. This monitoring is only active, if this module
has been selected.
W050:
Profib. Mod.(Adr. 31)
The Profibus module on address 31 does not r
spond. This monitoring is only active, if this module
has been selected.
iCommand
52
Compressor type
The on "W034: "Speed reduction" programmed digital
input was opened. Delay 1 s.
All
The on "W034: Dryer" progr
ammed digital input was
no delay.
All
The on "W036: "Condensate drain" programmed
digi-
tal input was closed.
All
The on "W037: "Air filter" programmed digital input
was closed. Monitoring starts after 15 minutes. Tri
g-
gering of warning without delay.
All
The on "W038: "Oil/oil filter" programmed dig
ital input
was closed. Monitoring starts after 15 minutes. Tri
g-
gering of warning without delay.
All
The on "W039: "Oil separator" programmed digital
input was closed. Monitoring starts after 15 minutes.
Triggering of warning without
delay.
All
At least one of the configured MK200 expansion mo
d-
ules is not answering (possible addresses 8 to 30).
All
The analogue output module on address 1 does not
respond. This monitoring is only active
, if this module
has been activated.
All
The LLC module on address 2 does not respond. This
monitoring is only active in LLC master operation du
r-
ing digital control of the LLC slave.
All
The expansion
module on address 4 does not re-
spond. This monitoring is only active, if this module
has been selected.
All
The expansion module on address 5 does not r
e-
spond. This monitoring is only active, if this module
has been selected.
All
The Profibus module on address 31 does not r
e-
spond. This monitoring is only active, if this module
has been selected.
All
iCommand – Touch
iCommand
- Touch
Compressor type