iCommand Manual

CAP-836
2.2
Brief description
2.3
Operating modes
Overview
Safety pressure
iCommand
12
Brief description
The ICOMMAND - BASIC controller serves
to display operating data/the compressor state
to switch
on/off the compressor/the compressed air generation
to program the compressor and the compressed air generation.
Operating modes
Three
operating modes can be set using the controller.
Operating
mode
Description
Automatic
operation
After reaching the switch-
off pressure, the
system switches to idle for the duration of the
idle time (run-
on). After the run
elapsed, the motor switches off. The
compressor can start up by itself
the machine drops below the switch
pressure.
Load/idle
operation
The compressor switches between "Load" and
"Idle" operation; i.e. there is an unlimited run
Basic load
switching
mode (BLS
mode)
The switch on/off pressure set is not
account by the controller. The compressor is
controlled by a superior controller.
The safety pressure is the sum of the set maximum pressure
the pressure exceeds the value of the safety pressure, the compressor
is switched off with a fault message. If the maximum pressure is
exceeded by
7
psi, a warning appears on the display.
iCommand
- Basic
to display operating data/the compressor state
on/off the compressor/the compressed air generation
to program the compressor and the compressed air generation.
operating modes can be set using the controller.
off pressure, the
system switches to idle for the duration of the
on). After the run
-on time has
elapsed, the motor switches off. The
compressor can start up by itself
at any time if
the machine drops below the switch
-on
The compressor switches between "Load" and
"Idle" operation; i.e. there is an unlimited run
-on.
The switch on/off pressure set is not
taken into
account by the controller. The compressor is
controlled by a superior controller.
The safety pressure is the sum of the set maximum pressure
+14 psi. If
the pressure exceeds the value of the safety pressure, the compressor
is switched off with a fault message. If the maximum pressure is
psi, a warning appears on the display.