Product Manual

Maintenance
CAP-834
36
SERVICE INTERVALS (HOURS)
DESCRIP-
TION
PART#
QTY
DLY.
WKLY.
YRLY
500
2 000
4 000
6 000
8 000
10 000
12 000
14 000
16 000
18 000
20 000
22 000
24 000
2000/
6000
Hour
Ser-
vice Kit
FSK-
26NX4-6
1
FSK-
26NX8-15
4000
Hour
Ser-
vice Kit
FSK-
4NX4-6
1
FSK-
4NX8-15
8000
Hour
Ser-
vice Kit
FSK-
8NX4-6
1
FSK-
8NX15-6
Change
Lubricant
2
Use
CurtisLubePl
us FSC-8000
5
US
G
1
Notes:
1) Initial 500 h only. Follow regular intervals thereafter.
2) Change oil yearly if operating under 8000 h. Lubricant may require more frequent changes de-
pending on operating environment, especially high temperatures, and running conditions. Refer
to
Appendix 10.2 Oil change intervals at elevated temparatures.
3) Do not tamper with relief valve setting - it is factory set - only check operation! Tampering will
void warranty and result may cause severe injury or death.
4) Replace as necessary or every 5 years.
* The maintenance intervals described herein are for normal operating condition in clean and well
ventilated environments. Frequency of intervals will increase for non-standard environments.
Please contact your authorized FS-CURTIS distributor for more information and recommenda-
tions.
Service Kits:
2000 & 6000 Hours = inlet air filter + oil-filter
4000 Hours = inlet air filter + oil-filter + air/oil separator
8000 Hours = inlet air filter + oil-filter + air/oil separator + inlet vlv. kit + thermo-vlv kit +
min. pres. vlv. kit + enclosure filters