Datasheet

System configurator and order-information guide
A
PRIMERGY RX100 S7p Status 2012-04-30
Basic unit (for 19" racks) with SATA RAID
(can be upgraded by Modular SAS RAID)
without CPU and Memory
- One CPU ( first CPU ) has to be configured
additionally for a base configuration
- One memory kit has to be configured
for a base configuration
SAS/SATA LFF (3.5") version with:
- 2-port SAS backplane for 2 hot plug
LFF (3.5") SAS/SATA HDDs incl. cables for connection
to the onboard SATA or plug in SAS controller
- SAS/SATA LFF (3.5") Base Unit
standard PSU S26361-K1385-V103
hot plug PSU / red. Fan
S26361-K1385-V203
SAS/SATA SFF (2.5") version with:
- 4-port SAS backplane for 4 hot plug
SFF (2.5") SAS/SATA HDDs incl. cables for connection
to the onboard SATA or plug in SAS controller
- SAS SFF (2.5") Base Unit
standard PSU S26361-K1385-V303
hot plug PSU / red. fan S26361-K1385-V403
S26361-F3552-E1
TPM Module
Trusted Platform Module on Motherboard
Use according to import restrictions
max. 1x per system
For Base Units with hot plug PSU only (V203, V403)
For later conversion of basic units with standard power supply
S26113-F575-E10 to hot plug power supply, the following kit is available:
2nd power supply module (PSU) 1.) hot plug PS upgrade kit, incl. 1 PS module S26113-F547-L10
450W / 94% efficiency (platinum)
+ Fan + PDU + PSU Cage (no power cord included)
for redundancy of BU V203/V403 Conversion standard into hot plug PS
occupies one bay for After upgrade, the Std. PSU can not be used anymore
hot plug power supply 2.) Supplementary power supply module S26113-F575-L10
max. 1x per system
for redundancy or repair (no power cable included!)
3.) Please order appropriate power cord additionally:
Powercord for rack, 4m, grey, IEC320 C13->C14 connect. T26139-Y1968-L10
PRIMECENTER Rack
Power Cord USA / Canada, 1.8m, grey
T26139-Y1742-L10
S26361-F2735-E175 S26361-F2735-E111 S26361-F2735-L175
RMK-F1_DI_CMA_QRL_LV
No Rackmount-Kit option
RMK-F1_DI_CMA_QRL_LV
telescopic drop-in rail, full extr.
Only for loose deliveries for loose delivery
1-hand-mounting
No mounting in racks possible
RMK - 1 pair consisting of
max. 1x per system
S26361-F2735-L10
- vario carrier length variable Adapter angle PC/DC-Rack, till 50Kg
with quick release lever support necessary for mounting RMKs in
- telescopic drop-in rails asymmetrical racks
with CMA adapter
1x per system
B
S26361-F2735-L7
Lateral cable management
can only be mounted
in asymmetrical PRIMECENTER
S26361-F4530-E11 S26361-F4530-E10 S2 or new M1 racks in 1U above RMK
Mounting 1U server in asymmetrical
Mounting in symmetrical racks
racks with 1U support bracket (no support bracket needed)
S26361-F2735-E81
Cable mgmt. arm for 1U Server Cable Management Arm (CMA)
S26361-F2735-L81
- for Fujitsu PRIMECENTER and
can only be used for FTS RMKs
Cable management arm for 1U Server
PRIMECENTER M1 racks with CMA adapter for loose delivery
- for 3rd Party racks
1x per system
S26361-F2735-L7
Lateral cable management (optionally)
can only be mounted
in asymmetrical PRIMECENTER
S26361-F1647-E302
S2 or new M1 racks in 1U above RMK
Installation ex works for one
server or subsystem.
"Rack-mounting ex factory"
Hereby the rack will be delivered This service is to be ordered once
completely pre-mounted and per installable server/storage
all wired connections are tested.
subsystem, in order to get the
With PCR S2 12U, 24U, 38U and server/storage subsystem
PRC M1 16U, 24U, 42U:
mounted into the racks.
Systems and components In case of the 46 U PCR S2
will be delivered installed in the rack this service has to be ordered,
With PCR S2 racks 46U:
to get the mounting kits and the
Systems and components cables installed.
will be delivered separately
To be ordered only together with
a PRIMECENTER rack
PCR S2 e.g. S26361-K826-V10x
new PCR M1 e.g. S26361-K827-Vxxx
refer PCR S2 or M1 rack configurator
max. 1x per System PRIMERGY Classic 19" rack is not supported
B
Fujitsu Technology Solutions x86 PRIMERGY Server 8 of 18