Installation Instructions

EN
23
7.2 Mounting the handles on stainless front
NOTE
To mount the handles onto the door and the drawer
operate as follows:
Operate as follows:
Insert the handle ends onto the supports already installed
on the door and the drawer [ 1 ].
1
Screw in the Allen screws available on the handle [ 2 ].
2
The screws must be tightened in by means of a 2.5 mm
(1/8”) hex wrench.
7.3 Ventilation
Professional Built-In Series
A forced air system assures ventilation through a grille
positioned in the lower front part of the unit. If the kitchen
design includes a kickplate, the latter has to be entirely in
order to maintain a satisfactory air flow, as described in the
drawing.
Holes can be in any shape and size, as long as the total
area of the area equals 50% of the kickplate area.
In this case, to guarantee a better air flow, it is advisable
to remove the front grille included with the unit. The grille
is secured to the unit with magnetic plates and can be
easily removed even by the end user, to provide for regular
cleaning procedures and dust removal.
If the grille is partially covered by the kitchen kickplate, it
is advisable to remove the grille in order to provide for a
better airflow.
A
B
C
C
SERIES 36” SERIES 24”
A
860 (33 7/8”) 560 (22”)
B
> 100 (4”)
C
10 (3/8”)
The air intake and outlet must not be blocked or covered
entirely. The condenser must to be dusted/cleaned on a
regular basis.